Show simple item record

dc.contributor.advisorErnest Moniz and Ahmed Ghoniem.en_US
dc.contributor.authorToukan, Ibrahim (Ibrahim Khaled)en_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Mechanical Engineering.en_US
dc.date.accessioned2013-04-12T19:37:35Z
dc.date.available2013-04-12T19:37:35Z
dc.date.copyright2012en_US
dc.date.issued2012en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/78540
dc.descriptionThesis (S.M.)--Massachusetts Institute of Technology, Engineering Systems Division; and, (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2012.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (p. 83-85).en_US
dc.description.abstractEnhanced oil recovery (EOR) through carbon dioxide (CO₂) sequestration from anthropogenic sources has been gaining attention in policy circles. In particular, it is viewed as a potential way to help accelerate the deployment of carbon capture and sequestration (CCS) technologies. The interest in the EOR-CCS model stems from the economic, geologic and regulatory benefits this model offers when compared to the waste-driven CCS model that utilizes saline aquifers for CO₂ storage. However, there are still some major challenges impeding the deployment of the EOR-CCS model; chief among these challenges is the mismatch between CO₂ supplies from anthropogenic sources and CO₂ demand from EOR operations. One potential way to address this challenge is through a CO₂ stacked storage system. A CO₂ stacked storage system utilizes brine formations adjacent to EOR oilfields for the purpose of storing any additional quantities of CO₂ the EOR operation cannot handle. The concept of a stacked storage system with focus on CO₂ supplies from coal-fired power plants was analyzed using a case study. A U.S. coal-fired power plant and a U.S. EOR oilfield were used to model a stacked storage system in order to determine the economic and technical viability of such a model. More specifically, this thesis has three main objectives. The first is to determine the overall cost of implementing the stacked storage system. The overall cost of the system came to approximately $90 per ton of CO₂ avoided.en_US
dc.description.statementofresponsibilityby Ibrahim Toukan.en_US
dc.format.extent122 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectEngineering Systems Division.en_US
dc.subjectMechanical Engineering.en_US
dc.titleExploring the value proposition of integrating back-up saline storage into anthropogenic CO₂ supplied EOR operationsen_US
dc.typeThesisen_US
dc.description.degreeS.M.en_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.contributor.departmentMassachusetts Institute of Technology. Engineering Systems Division
dc.identifier.oclc836778376en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)