Show simple item record

dc.contributor.advisorBrian W. Anthony.en_US
dc.contributor.authorInamdar, Tejas Satishen_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Mechanical Engineering.en_US
dc.date.accessioned2013-06-17T19:55:28Z
dc.date.available2013-06-17T19:55:28Z
dc.date.copyright2013en_US
dc.date.issued2013en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/79316
dc.descriptionThesis (M. Eng. in Manufacturing)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2013.en_US
dc.descriptionCataloged from PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (p. 93-94).en_US
dc.description.abstractThe reagent delivery mechanism in a point-of-care, HIV diagnostic, microfluidic device is studied. Reagents held in an aluminum pack are released on the opening of a fluidic seal. Fluidic seals, controlling the flow of reagents, are characterized to reduce anomalies in the desired flow pattern. The nature of the current seal was investigated. Four seal patterns - line hemisphere, line flat, chevron hemisphere and chevron flat were created and tested for reagent delivery using a flow sensor and a force gauge. Preliminary experiments suggested that one of the patterns - "line-flat" - resulted in fewer flow anomalies. A parameter scoping exercise involving sealing process parameters (temperature, time, gap and distance) was performed for the line flat seal. The findings of this research can be divided into three categories - 1) bonding phenomenon in current seals, 2) influence of seal pattern on flow and rupture mechanics and 3) process parameters which result in the least flow anomalies. The current seal is found to be a bond between the exposed aluminum on the lid film and the heat seal coating on the dome film. The two chevron patterns result in large amounts of flow anomalies, the line hemisphere pattern also resulted in some instances of flow anomalies. The line-flat pattern creates a seal with the least flow anomalies. A specific set of temperature, time, gap and distance which minimizes flow anomalies was found. The flow performance of the reservoir improved and delamination decreased as the distance of the seal from the reservoir was reduced. The thesis also develops a model to better understand the deformation of the reagent carrying dome and flow dynamics prior to and following the opening of the seal. The dome deformation model provides a framework for relating volume, delamination and flow rate to the geometry and material properties of the reservoir pack.en_US
dc.description.statementofresponsibilityby Tejas Satish Inamdar.en_US
dc.format.extent96 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectMechanical Engineering.en_US
dc.titleManufacturing of lab-on-a-chip devices : characterizing seals for on-board reagent deliveryen_US
dc.typeThesisen_US
dc.description.degreeM.Eng.in Manufacturingen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Mechanical Engineering
dc.identifier.oclc847845731en_US


Files in this item