dc.description.abstractNatural ventilation in buildings is capable of reducing energy consumption while maintaining a comfortable indoor at the same time. It is important that natural ventilation is taken into consideration in the early design stage, probably through simulation program. However, existing simulation programs are limited because of their model assumption, simulation efficiency and user friendliness. In this document a simulation program, CoolVent, is presented. It implements a multi-node, thermal and energy coupled model to simulate natural ventilation in buildings. The program is validated to be effective and efficient in simulation. Combined with the DOE building database, CoolVent evaluates the performance of different ventilation modes in different types of building and weather conditions. The second half of this thesis includes a detailed on-site monitoring study of a naturally ventilated building in Boston. It details the post-occupancy system characteristics. The monitoring results have also been compared with CoolVent. The simulation results are verified by comparing with the monitored ones. The program is then used to evaluate the potential of improved operation.en_US
dc.description.statementofresponsibilityby Haofan Cheng.en_US
dc.format.extent121 p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectArchitecture.en_US
dc.titleEvaluating the performance of natural ventilation in buildings through simulation and on-site monitoringen_US
dc.typeThesisen_US
dc.description.degreeS.M.in Building Technologyen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Architecture
dc.identifier.oclc859798926en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record