Show simple item record

dc.contributor.advisorLeslie K. Norford.en_US
dc.contributor.authorBlum, David H. (David Henry)en_US
dc.contributor.otherMassachusetts Institute of Technology. Department of Architecture.en_US
dc.date.accessioned2013-11-18T17:34:17Z
dc.date.available2013-11-18T17:34:17Z
dc.date.copyright2013en_US
dc.date.issued2013en_US
dc.identifier.urihttp://hdl.handle.net/1721.1/82162
dc.descriptionThesis (S.M. in Building Technology)--Massachusetts Institute of Technology, Dept. of Architecture, 2013.en_US
dc.descriptionThis electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.en_US
dc.descriptionCataloged from student-submitted PDF version of thesis.en_US
dc.descriptionIncludes bibliographical references (p. 113-119).en_US
dc.description.abstractOutput variability and prediction difficulties with respect to solar and wind electricity resources increase the requirement of grid-scale reserve capacity and add strain to existing firm generators used for reserves and other ancillary services. Residential and commercial buildings account for a large portion of the electricity consumed in the U.S. and can play a significant role in smart grids to help meet challenges brought about by intermittent renewable generation. High resolution power consumption and HVAC performance data measured in a real building was used to identify real-world operational qualities of VAV systems to be considered by building researchers and building practitioners. This includes the relative magnitude of building power loads, the direct and indirect relationships between environmental conditions and HVAC power consumption, the discrete operation of staged or cycled power loads, and the presence of HVAC operational faults. Also, three static pressure adjustment tests were performed over a one day period. Results showed that fan and terminal unit controllers responded within two minutes and system air flowrate was strongly related to power consumption. Dynamic models were created in order to simulate the performance of a VAV system providing spinning reserves by four different common demand response strategies: zone air dry bulb temperature setpoint adjustment (ZDBA), duct static pressure setpoint adjustment (SPA), supply air temperature adjustment (STA), and chilled water temperature adjustment (CWA). Simulations were run over ranges of implementation and cooling load intensities and the results were used to create characteristic curves for each strategy, which map performance in terms of system power consumption reduction, system airflow reduction, and zone temperature rise. Inflection points on the curves that delineate performance effectiveness are found to result from maximum or minimum terminal unit damper positions. In the future, the development of mathematical functional forms of these characterization curves could help predict and optimize the performance of VAV systems in providing ancillary services to electricity networks.en_US
dc.description.statementofresponsibilityby David H. Blum.en_US
dc.format.extent139, 2, [3] p.en_US
dc.language.isoengen_US
dc.publisherMassachusetts Institute of Technologyen_US
dc.rightsM.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.en_US
dc.rights.urihttp://dspace.mit.edu/handle/1721.1/7582en_US
dc.subjectArchitecture.en_US
dc.titleAnalysis and characterization of ancillary service demand response strategies for variable air volume HVAC systemsen_US
dc.typeThesisen_US
dc.description.degreeS.M.in Building Technologyen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Architecture
dc.identifier.oclc861187067en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record