MIT Libraries homeMIT Libraries logoDSpace@MIT

MIT
View Item 
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Doctoral Theses
  • View Item
  • DSpace@MIT Home
  • MIT Libraries
  • MIT Theses
  • Doctoral Theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

A study of loading parameters that affect DNA electrophoresis in microdevices

Author(s)
Vázquez, Maribel, 1971-
Thumbnail
DownloadFull printable version (12.87Mb)
Other Contributors
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Advisor
Daniel Ehrlich and Gareth McKinley.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
Electrophoresis of DNA has become particularly attractive in today's age of bio-technology. The goal of the present research is to optimize the the gel-loading and sample-loading protocols used prior to electrophoresis within microfabricated devices. During gel-loading, electrophoretic channels are filled with a polymer matrix prior to their use in DNA separations. The injection rate is constrained by the desire to minimize shear-induced degradation of the polymer molecules. In this study, measurements of the zero shear-rate viscosity of linear polyacrylamide (LPA) solutions are used to determine the LPA molecular weight before and after gel-loading protocols. The results demonstrate induced molecular degradation of polymer molecules even when matrixes are injected at minimal flow rates of 1 microliter per minute. Next, digital images are used to analyze the electrophoretic migration of DNA samples during conventional sample-loading and injection protocols. Experimental data illustrate that the 'stacked' DNA sample plug is comprised of distinct concentrated populations of DNA molecules that migrate with the same mechanism of transport. This study produced a detailed exploration of the injection process as well as a standardized method to measure the level of 'stacking' exhibited by a system. Additionally, a novel high voltage injection protocol correlates increases in resolution and separation with higher levels of sample stacking during injection. Developments realized through these experiments demonstrate great promise for upgraded electrophoretic protocols and future microdevices.
Description
Thesis (Sc. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2001.
 
Includes bibliographical references (p. 206-220).
 
Date issued
2001
URI
http://hdl.handle.net/1721.1/8302
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Mechanical Engineering.

Collections
  • Doctoral Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries homeMIT Libraries logo

Find us on

Twitter Facebook Instagram YouTube RSS

MIT Libraries navigation

SearchHours & locationsBorrow & requestResearch supportAbout us
PrivacyPermissionsAccessibility
MIT
Massachusetts Institute of Technology
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.