Soft pneumatic artificial muscles with low threshold pressures for a cardiac compression device

Author(s)
Obiajulu, Steven (Steven C.)
Thumbnail
DownloadFull printable version (6.062Mb)
Other Contributors
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Advisor
Daniel D. Frey.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
In this paper, I present the design, fabrication and characterization of fully soft pneumatic artificial muscles (PAMs) with low threshold pressures that are intended for direct cardiac compression (DCC). McKibben type PAMs typically have a threshold pressure of at least lOOkPa and require rigid end fittings which may damage soft tissue and cause local stress concentrations, and thus failure points in the actuator. The actuator design I present is a variant on the McKibben PAM with the following key differences: the nylon mesh is embedded in the elastomeric tube, and closure of the end of the tube is achieved without rigid ends. The actuators were tested to investigate the effects of mesh geometry and elastomer material on force output, contraction, and rise time. Lower initial braid angles and softer elastomer materials provided the best force, contraction, and rise times; Up to 50N of force, 24% contraction, and response times of 0.05s were achieved at 100kPa. The actuators exhibited low threshold pressures (<5kPa) and high rupture pressures (138kPa - 720kPa) which suggest safe operation for the DCC application. These results demonstrate that the actuators can achieve forces, displacements, and rise times suitable to assist with cardiac function.
Description
Thesis (S.B.)--Massachusetts Institute of Technology, Department of Mechanical Engineering, 2013.
 
Cataloged from PDF version of thesis.
 
Includes bibliographical references (pages 45-47).
 
Date issued
2013
URI
http://hdl.handle.net/1721.1/83730
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Mechanical Engineering.

Collections
  • Undergraduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.