dc.contributor.author | Hong, Stanley S. | |
dc.contributor.author | Freeman, Dennis M. | |
dc.date.accessioned | 2014-05-30T19:59:44Z | |
dc.date.available | 2014-05-30T19:59:44Z | |
dc.date.issued | 2006-10 | |
dc.date.submitted | 2006-05 | |
dc.identifier.issn | 10833668 | |
dc.identifier.issn | 1560-2281 | |
dc.identifier.uri | http://hdl.handle.net/1721.1/87598 | |
dc.description.abstract | The possibility of measuring subnanometer motions with micron scale spatial resolution in the intact mammalian cochlea using Doppler optical coherence microscopy (DOCM) is demonstrated. A novel DOCM system is described that uses two acousto-optic modulators to generate a stable 500-kHz heterodyne frequency. Images and motion measurements are obtained using phase-resolved analysis of the interference signal. The DOCM system permits imaging with micron-scale resolution and 85-dB sensitivity and motion measurements with 100-kHz bandwidth, directional discrimination, and 30-pm/Hz[superscript 0.5] noise floor. Images and motion measurements are presented that demonstrate the ability to resolve motions of structures of interest in a mammalian cochlea in vitro including the basilar membrane, reticular lamina, tectorial membrane, and outer hair cells. | en_US |
dc.description.sponsorship | National Institutes of Health (U.S.) (Grant 1-R21-DC007111-01) | en_US |
dc.language.iso | en_US | |
dc.publisher | SPIE | en_US |
dc.relation.isversionof | http://dx.doi.org/10.1117/1.2358702 | en_US |
dc.rights | Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. | en_US |
dc.source | SPIE | en_US |
dc.title | Doppler optical coherence microscopy for studies of cochlear mechanics | en_US |
dc.type | Article | en_US |
dc.identifier.citation | Hong, Stanley S., and Dennis M. Freeman. “Doppler Optical Coherence Microscopy for Studies of Cochlear Mechanics.” Journal of Biomedical Optics 11, no. 5 (2006): 054014. © 2006 SPIE | en_US |
dc.contributor.department | Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science | en_US |
dc.contributor.department | Massachusetts Institute of Technology. Research Laboratory of Electronics | en_US |
dc.contributor.mitauthor | Hong, Stanley S. | en_US |
dc.contributor.mitauthor | Freeman, Dennis M. | en_US |
dc.relation.journal | Journal of Biomedical Optics | en_US |
dc.eprint.version | Final published version | en_US |
dc.type.uri | http://purl.org/eprint/type/JournalArticle | en_US |
eprint.status | http://purl.org/eprint/status/PeerReviewed | en_US |
dspace.orderedauthors | Hong, Stanley S.; Freeman, Dennis M. | en_US |
dc.identifier.orcid | https://orcid.org/0000-0001-6309-0910 | |
mit.license | PUBLISHER_POLICY | en_US |
mit.metadata.status | Complete | |