dc.description.abstractThe possibility of measuring subnanometer motions with micron scale spatial resolution in the intact mammalian cochlea using Doppler optical coherence microscopy (DOCM) is demonstrated. A novel DOCM system is described that uses two acousto-optic modulators to generate a stable 500-kHz heterodyne frequency. Images and motion measurements are obtained using phase-resolved analysis of the interference signal. The DOCM system permits imaging with micron-scale resolution and 85-dB sensitivity and motion measurements with 100-kHz bandwidth, directional discrimination, and 30-pm/Hz[superscript 0.5] noise floor. Images and motion measurements are presented that demonstrate the ability to resolve motions of structures of interest in a mammalian cochlea in vitro including the basilar membrane, reticular lamina, tectorial membrane, and outer hair cells.en_US
dc.description.sponsorshipNational Institutes of Health (U.S.) (Grant 1-R21-DC007111-01)en_US
dc.language.isoen_US
dc.publisherSPIEen_US
dc.relation.isversionofhttp://dx.doi.org/10.1117/1.2358702en_US
dc.rightsArticle is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use.en_US
dc.sourceSPIEen_US
dc.titleDoppler optical coherence microscopy for studies of cochlear mechanicsen_US
dc.typeArticleen_US
dc.identifier.citationHong, Stanley S., and Dennis M. Freeman. “Doppler Optical Coherence Microscopy for Studies of Cochlear Mechanics.” Journal of Biomedical Optics 11, no. 5 (2006): 054014. © 2006 SPIEen_US
dc.contributor.departmentMassachusetts Institute of Technology. Department of Electrical Engineering and Computer Scienceen_US
dc.contributor.departmentMassachusetts Institute of Technology. Research Laboratory of Electronicsen_US
dc.contributor.mitauthorHong, Stanley S.en_US
dc.contributor.mitauthorFreeman, Dennis M.en_US
dc.relation.journalJournal of Biomedical Opticsen_US
dc.eprint.versionFinal published versionen_US
dc.type.urihttp://purl.org/eprint/type/JournalArticleen_US
eprint.statushttp://purl.org/eprint/status/PeerRevieweden_US
dspace.orderedauthorsHong, Stanley S.; Freeman, Dennis M.en_US
dc.identifier.orcidhttps://orcid.org/0000-0001-6309-0910
mit.licensePUBLISHER_POLICYen_US
mit.metadata.statusComplete


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record