Optimizing interventions for the treatment of vascular flow disruptions

Author(s)
Boval, Brett Lawrence
Thumbnail
DownloadFull printable version (10.91Mb)
Other Contributors
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Advisor
Elazer R. Edelman.
Terms of use
M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582
Metadata
Show full item record
Abstract
All tissues rely on perfusion and therefore intact blood flow. When flow is disrupted the coupled interaction between the functional and fluid domains of a tissue is impeded and viability is lost. Aortic stenosis is a paradigmatic example of vascular flow disruption. In health there is no gradient across the aortic valve and pressure generated in the left ventricle is transmitted without loss to the aorta. Pressure gradients across the valve force the left ventricle pressure to rise accordingly, straining this proximal pumping chamber, and when it can no longer compensate, affecting distal blood flow and organ perfusion. Aortic stenosis is common and impactful, highly morbid and when symptomatic almost inevitably fatal within a few years. New interventions to address vascular flow disruptions, such as transcatheter aortic valve replacements (TAVR), have significantly improved quality of life and life expectancy. However, these emerging technologies involve unique delivery modes and anchoring mechanisms that require the prosthesis to intimately interact with the aortic wall. As aortic stenosis is marked by asymmetric and inhomogeneous accumulations of calcium there is the potential for suboptimal alignment of the valve. A framework is presented to account for valve-tissue interactions in the setting of such asymmetric deposits. We compared paired pre and post procedural computed tomographic (CT) scans of patients who had severe adverse events with TAVR. A range of scenarios are considered and two patient cases are presented - with one normal deployment and the other with device buckling failure. The work highlights the ongoing need for better understanding of how calcium distribution in the aortic root environment affects a patient's susceptibility to clinical complications.
Description
Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2014.
 
Cataloged from PDF version of thesis.
 
Includes bibliographical references (pages 85-94).
 
Date issued
2014
URI
http://hdl.handle.net/1721.1/93858
Department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Publisher
Massachusetts Institute of Technology
Keywords
Mechanical Engineering.

Collections
  • Graduate Theses

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

OA StatisticsStatistics by CountryStatistics by Department
MIT Libraries
PrivacyPermissionsAccessibilityContact us
MIT
Content created by the MIT Libraries, CC BY-NC unless otherwise noted. Notify us about copyright concerns.