<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-22T12:38:40Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/100886" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/100886</identifier><datestamp>2022-01-13T07:54:05Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Evelyn N. Wang.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Queeney, John (John Keeler)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2016-01-15T21:10:59Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2016-01-15T21:10:59Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2015</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2015</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/100886</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">933610023</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2015.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 28).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Car air conditioning systems cool the entire cabin, which is inefficient, as only the air surrounding the passengers needs to be cooled to realize a similar effect. These air conditioning units draw large amounts of power, enough to be detrimental to fuel efficiency. This presents problems for cars with smaller engines and electric cars that lack the battery capacity to provide adequate cooling with traditional air conditioning technology. A novel solution to these problems uses evaporative cooling via jumping droplet condensation on superhydrophobic surfaces to provide localized cooling with 100 times less power input. Jumping droplet condensation takes place when microscale droplets coalesce on superhydrophobic surfaces and excess surface energy is converted to kinetic energy, resulting in droplets that jump perpendicularly off the surface. As these droplets fall through the air, they evaporate, cooling the surrounding air and providing localized cooling. To test this technology, a prototype device was designed, fabricated, and tested at different relative humidities in an environmental chamber. Cooling of up to 4.8°C relative to ambient was achieved at 80% relative humidity, 4 cm from the condensing surface. This result suggests an optimal humidity for the operation of these devices and prompts further lines of study for the optimization of this technology.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by John Queeney.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">38 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Evaporative cooling via jumping droplet condensation on superhydrophobic surfaces for localized car air conditioning</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="b1646486-d649-4b74-a0be-e7d41bd40f74">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Evaporative cooling via jumping droplet condensation on superhydrophobic surfaces for localized car air conditioning&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2015&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Queeney, John (John Keeler)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Car air conditioning systems cool the entire cabin, which is inefficient, as only the air surrounding the passengers needs to be cooled to realize a similar effect. These air conditioning units draw large amounts of power, enough to be detrimental to fuel efficiency. This presents problems for cars with smaller engines and electric cars that lack the battery capacity to provide adequate cooling with traditional air conditioning technology. A novel solution to these problems uses evaporative cooling via jumping droplet condensation on superhydrophobic surfaces to provide localized cooling with 100 times less power input. Jumping droplet condensation takes place when microscale droplets coalesce on superhydrophobic surfaces and excess surface energy is converted to kinetic energy, resulting in droplets that jump perpendicularly off the surface. As these droplets fall through the air, they evaporate, cooling the surrounding air and providing localized cooling. To test this technology, a prototype device was designed, fabricated, and tested at different relative humidities in an environmental chamber. Cooling of up to 4.8°C relative to ambient was achieved at 80% relative humidity, 4 cm from the condensing surface. This result suggests an optimal humidity for the operation of these devices and prompts further lines of study for the optimization of this technology.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>