<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T00:00:17Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/101339" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/101339</identifier><datestamp>2026-06-17T14:42:05Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Benjamin J. Vakoc.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Siddiqui, Meena</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Harvard--MIT Program in Health Sciences and Technology.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Harvard University--MIT Division of Health Sciences and Technology</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2016-02-29T15:01:16Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2016-02-29T15:01:16Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2015</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2015</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/101339</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">938897920</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: Ph. D., Harvard-MIT Program in Health Sciences and Technology, 2015.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 147-152).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Optical coherence tomography (OCT) allows label-free, three-dimensional imaging of tissue structure. Current implementations of OCT can either image over long depth ranges at slow imaging speeds, or over limited depth ranges at high speeds. Here, we describe a new OCT paradigm that supports simultaneous high speed and long depth range imaging through subsampling bandwidth compression. We show that this requires replacing the conventional wavelength-swept OCT laser source with a wavelength-stepped laser. First we validated this concept by modifying a slow, conventional wavelength-swept source with an intra-cavity Fabry-Perot etalon to provide a wavelength-stepped output. Using this source in an existing OCT system, we show that we can passively compress signals across a large depth range into a limited RF bandwidth. Next, to demonstrate high-speed optical domain subsampled imaging, we developed a novel wavelength-stepped laser source based on intra-cavity pulse compression/stretching; this source provided an A-line rate of ~19 MHz. We then built a polarization-based quadrature interferometer to remove imaging artifacts induced by subsampling and comple-conjugate ambiguity. A calibration and error compensation method was developed to fully remove residual artifacts in the image. We combined the high speed laser and the interferometer to demonstrate the first OCT camera-like imaging across several centimeters of depth range. The optically subsampled OCT technology developed in this work may offer a new three-dimensional camera platform for endoscopic and intraoperative imaging applications.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Meena Siddiqui.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">152 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Harvard--MIT Program in Health Sciences and Technology.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Development of a three-dimensional camera based on subsampled optical coherence tomography (OCT)</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Development of a 3-dimensional camera based on subsampled optical coherence tomography (OCT)</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Development of a 3-D camera based on subsampled optical coherence tomography (OCT)</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="620345e3-8410-4f0d-961d-d3f1c3e293ec">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Development of a three-dimensional camera based on subsampled optical coherence tomography (OCT)&lt;/Title>
   	&lt;Subtitle>Development of a 3-dimensional camera based on subsampled optical coherence tomography (OCT)&lt;/Subtitle>
   	&lt;Subtitle>Development of a 3-D camera based on subsampled optical coherence tomography (OCT)&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2015&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Siddiqui, Meena&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Harvard--MIT Program in Health Sciences and Technology.&lt;/Keyword>
   	&lt;Abstract>Optical coherence tomography (OCT) allows label-free, three-dimensional imaging of tissue structure. Current implementations of OCT can either image over long depth ranges at slow imaging speeds, or over limited depth ranges at high speeds. Here, we describe a new OCT paradigm that supports simultaneous high speed and long depth range imaging through subsampling bandwidth compression. We show that this requires replacing the conventional wavelength-swept OCT laser source with a wavelength-stepped laser. First we validated this concept by modifying a slow, conventional wavelength-swept source with an intra-cavity Fabry-Perot etalon to provide a wavelength-stepped output. Using this source in an existing OCT system, we show that we can passively compress signals across a large depth range into a limited RF bandwidth. Next, to demonstrate high-speed optical domain subsampled imaging, we developed a novel wavelength-stepped laser source based on intra-cavity pulse compression/stretching; this source provided an A-line rate of ~19 MHz. We then built a polarization-based quadrature interferometer to remove imaging artifacts induced by subsampling and comple-conjugate ambiguity. A calibration and error compensation method was developed to fully remove residual artifacts in the image. We combined the high speed laser and the interferometer to demonstrate the first OCT camera-like imaging across several centimeters of depth range. The optically subsampled OCT technology developed in this work may offer a new three-dimensional camera platform for endoscopic and intraoperative imaging applications.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>