<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T15:42:38Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/103465" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/103465</identifier><datestamp>2022-01-13T07:54:05Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Martin L. Culpepper.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Dias Carlson, Rachel (Rachel A.)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2016-07-01T18:42:41Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2016-07-01T18:42:41Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2016</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2016</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/103465</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">952320500</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2016.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 102-104).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The purpose of this work is to learn how the performance of a constraint system that interfaces with nonlinear elastic materials such as biological tissue can be predicted by a model. The direct application of this work is the determination of the feasibility of restraining awake and anesthetized mice skulls to submicron levels of movement for biological imaging applications without direct attachment to the skull. A device capable of restricting mouse skull movement to less than a micron in every direction without requiring the rigid attachment of a fixture to the skull would enable studies of bone marrow activity that are not currently possible. No existing work has attempted to determine the performance limits of a constraint system interfacing with nonlinear elastic material. This thesis introduces a model for determining the constraint system performance, and demonstrates how material properties may be tested to determine their relative significance and inclusion in the system model. The theoretical model is applied to the case of an awake mouse to demonstrate that a tissue-interfacing constraint system can only limit movement to hundreds of microns and is not capable of achieving the desired submicron level performance. For the case of an anesthetized mouse, the designed device is tested and achieves the desired sub-micron performance in all three axes for improved imaging capabilities in anesthetized mice.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Rachel Dias Carlson.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">105 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Precision constraint of deformable bodies for medical imaging applications</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="59228ca4-e8bc-4d2f-bf18-0473feb8b83c">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Precision constraint of deformable bodies for medical imaging applications&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2016&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Dias Carlson, Rachel (Rachel A.)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>The purpose of this work is to learn how the performance of a constraint system that interfaces with nonlinear elastic materials such as biological tissue can be predicted by a model. The direct application of this work is the determination of the feasibility of restraining awake and anesthetized mice skulls to submicron levels of movement for biological imaging applications without direct attachment to the skull. A device capable of restricting mouse skull movement to less than a micron in every direction without requiring the rigid attachment of a fixture to the skull would enable studies of bone marrow activity that are not currently possible. No existing work has attempted to determine the performance limits of a constraint system interfacing with nonlinear elastic material. This thesis introduces a model for determining the constraint system performance, and demonstrates how material properties may be tested to determine their relative significance and inclusion in the system model. The theoretical model is applied to the case of an awake mouse to demonstrate that a tissue-interfacing constraint system can only limit movement to hundreds of microns and is not capable of achieving the desired submicron level performance. For the case of an anesthetized mouse, the designed device is tested and achieves the desired sub-micron performance in all three axes for improved imaging capabilities in anesthetized mice.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication&gt;
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>