<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T11:44:59Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/106010" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/106010</identifier><datestamp>2026-06-06T00:49:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Roger I. Khazan and Michael A. Zhivich.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Holliman, John H., III</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2016-12-22T15:18:27Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2016-12-22T15:18:27Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2016</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2016</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/106010</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">965799996</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2016.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">This electronic version was submitted by the student author.  The certified thesis is available in the Institute Archives and Special Collections.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from student-submitted PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 89-94).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Real-time monitoring of physiological data can reduce the likelihood of injury in noncombat military personnel and first-responders. MIT Lincoln Laboratory is developing a tactical Real-Time Physiological Status Monitoring (RT-PSM) system architecture and reference implementation named OBAN (Open Body Area Network), the purpose of which is to provide an open, government-owned framework for integrating multiple wearable sensors and applications. The OBAN implementation accepts data from various sensors enabling calculation of physiological strain information which may be used by squad leaders or medics to assess the team's health and enhance safety and effectiveness of mission execution. Security in terms of measurement integrity, confidentiality, and authenticity is an area of interest because OBAN system components exchange sensitive data in contested environments. In this thesis, I analyze potential cyber-security threats and their associated risks to a generalized version of the OBAN architecture. Using the threat analysis, I identify security requirements for RT-PSM systems and describe the development of a secure RT-PSM system, called the Authenticated and Trustworthy Open Body Area Network (AUTOBAN) proof-of-concept implementation, that meets those requirements using cryptographic primitives that operate efficiently on low-power embedded devices. The threat analysis and proof-of-concept application, are intended to inform the development of secure RT-PSM architectures and implementations.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by John H. Holliman, III.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.Eng.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">AUTOBAN : secure low-power body area network for real-time physiological status monitoring</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Secure low-power body area network for real-time physiological status monitoring</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="53b61739-9774-4ed7-ae46-9953bc328f7a">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>AUTOBAN : secure low-power body area network for real-time physiological status monitoring&lt;/Title>
   	&lt;Subtitle>Secure low-power body area network for real-time physiological status monitoring&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2016&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Holliman, John H., III&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
   	&lt;Abstract>Real-time monitoring of physiological data can reduce the likelihood of injury in noncombat military personnel and first-responders. MIT Lincoln Laboratory is developing a tactical Real-Time Physiological Status Monitoring (RT-PSM) system architecture and reference implementation named OBAN (Open Body Area Network), the purpose of which is to provide an open, government-owned framework for integrating multiple wearable sensors and applications. The OBAN implementation accepts data from various sensors enabling calculation of physiological strain information which may be used by squad leaders or medics to assess the team&amp;apos;s health and enhance safety and effectiveness of mission execution. Security in terms of measurement integrity, confidentiality, and authenticity is an area of interest because OBAN system components exchange sensitive data in contested environments. In this thesis, I analyze potential cyber-security threats and their associated risks to a generalized version of the OBAN architecture. Using the threat analysis, I identify security requirements for RT-PSM systems and describe the development of a secure RT-PSM system, called the Authenticated and Trustworthy Open Body Area Network (AUTOBAN) proof-of-concept implementation, that meets those requirements using cryptographic primitives that operate efficiently on low-power embedded devices. The threat analysis and proof-of-concept application, are intended to inform the development of secure RT-PSM architectures and implementations.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>