<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T21:25:11Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/110884" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/110884</identifier><datestamp>2022-01-13T07:54:05Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Anastasios John Hart.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Rosenberg, Ron, S.M. Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2017-08-01T13:14:27Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2017-08-01T13:14:27Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2016</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2016</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/110884</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">994207801</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2016.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 187-192).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Rural Indian farmers lack an available, affordable, usable, and actionable means to diagnose soil health, which is a prerequisite for judicious application of fertilizer. Although government labs and mobile kits are available, these fail to meet the aforementioned qualities; as a result fewer than 5% of rural Indian farmers have ever performed a soil test. This thesis details the design and characterization of a point-of- use soil testing device, comprising a set of disposable ion-selective electrode (ISE) strips and a handheld electrochemical reader, which together transduce soil analyte concentrations into a numeric input for a mobile-phone based fertilizer recommendation engine. As a proof-of-concept, potassium (K+) selective electrodes are studied, because K+ is essential to plant growth and reproduction. The strips employ a simple two electrode system, wherein carbon nanotube and silver chloride inks are the electrode contacts, plasticizer-free butyl acrylate ion selective membranes are located on the working electrodes, and sodium-chloride doped polyvinyl butyral membranes provide stable reference potentials. The electrodes were fabricated by a combined screen printing and drop casting process, and the protocol, extraction solution, and reference potential stability were tuned to maximize ISE performance and repeatability. Using a mathematical model and supporting experiments, we verified that hydrogen selectivity determines the detection limit, and furthermore, that scientists can tune the ionophore-ionic site ratio to minimize this effect. Using the final electrode fabrication process, a set of 20 full ISE devices in the presence of 0.02M SrCl2 extraction solution were shown to have sub-uM detection limits and near-Nernstian average sensitivity (61 mV/decade). When compared to ICP data for a set of 30 soil samples using the final reader, the sensors demonstrated a 0.898 correlation factor. Workshops in India were conducted to determine user needs and corresponding product attributes, as well as a "usability index" for the system assessed across farmer demographics. The favorable system performance proves that solid-state ISEs are a promising technology for soil diagnostics in resource-constrained environments.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Ron Rosenberg.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">192 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Screen-printed ion selective electrodes for soil ion detection</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="55b74e07-b2ca-4e05-9ace-cb912ce60528">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Screen-printed ion selective electrodes for soil ion detection&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2016&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Rosenberg, Ron, S.M. Massachusetts Institute of Technology&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Rural Indian farmers lack an available, affordable, usable, and actionable means to diagnose soil health, which is a prerequisite for judicious application of fertilizer. Although government labs and mobile kits are available, these fail to meet the aforementioned qualities; as a result fewer than 5% of rural Indian farmers have ever performed a soil test. This thesis details the design and characterization of a point-of- use soil testing device, comprising a set of disposable ion-selective electrode (ISE) strips and a handheld electrochemical reader, which together transduce soil analyte concentrations into a numeric input for a mobile-phone based fertilizer recommendation engine. As a proof-of-concept, potassium (K+) selective electrodes are studied, because K+ is essential to plant growth and reproduction. The strips employ a simple two electrode system, wherein carbon nanotube and silver chloride inks are the electrode contacts, plasticizer-free butyl acrylate ion selective membranes are located on the working electrodes, and sodium-chloride doped polyvinyl butyral membranes provide stable reference potentials. The electrodes were fabricated by a combined screen printing and drop casting process, and the protocol, extraction solution, and reference potential stability were tuned to maximize ISE performance and repeatability. Using a mathematical model and supporting experiments, we verified that hydrogen selectivity determines the detection limit, and furthermore, that scientists can tune the ionophore-ionic site ratio to minimize this effect. Using the final electrode fabrication process, a set of 20 full ISE devices in the presence of 0.02M SrCl2 extraction solution were shown to have sub-uM detection limits and near-Nernstian average sensitivity (61 mV/decade). When compared to ICP data for a set of 30 soil samples using the final reader, the sensors demonstrated a 0.898 correlation factor. Workshops in India were conducted to determine user needs and corresponding product attributes, as well as a &amp;quot;usability index&amp;quot; for the system assessed across farmer demographics. The favorable system performance proves that solid-state ISEs are a promising technology for soil diagnostics in resource-constrained environments.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>