<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T16:21:22Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/115652" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/115652</identifier><datestamp>2022-01-13T07:54:05Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Daniel Frey.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Miller, Sally A</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2018-05-23T16:28:46Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2018-05-23T16:28:46Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2018</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2018</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/115652</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">1036985342</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2018.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 59-60).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Access to surgical care for people in remote settings and/or developing countries is limited: 30% of the world's population receives 75% of major operations [1]. In developing countries, up to a third of patients acquire a surgical site infection (SSI), which is nine times more likely than in developed countries [2]. An estimated 85,500 cases of HIV and hepatitis are contracted by obstetrical/gynecological providers every year, and 90% of those cases are the result of treating patients living in poverty. SurgiBox aims to address these issues by providing a portable, sterile operating environment for use in austere settings. Not only are patients protected from environmental hazards through the use of SurgiBox, but medical personnel are also shielded from patient fluids, blood, and aerosols. SurgiBox consists of a clear, disposable plastic enclosure that is adhered to the patient's surgical site and inflated with filtered air. Long gloves, similar those used in a glovebox, are integrated into the enclosure and used by the medical personnel to perform the surgery. Surgical instruments are sterilized before the surgery and are placed inside the enclosure prior to the procedure, but materials, or even a baby in the case of a cesarean section, can be passed in or out of the sterile field during the procedure through a resealable port. Particle count testing inside the enclosure shows that particle counts could be maintained at less than 25% of operating room standards for particles greater than 0.5 microns (OR standard: less than 83,000 particles/m3)and 0.3 microns (OR standard: less than 1,000,000 particles/m 3 ).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Sally A. Miller.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">63 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Design of an ultraportable surgical enclosure for low resource environments</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="0409bcc7-1cee-4ca3-9305-6876440d9c66">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Design of an ultraportable surgical enclosure for low resource environments&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2018&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Miller, Sally A&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Access to surgical care for people in remote settings and/or developing countries is limited: 30% of the world&amp;apos;s population receives 75% of major operations [1]. In developing countries, up to a third of patients acquire a surgical site infection (SSI), which is nine times more likely than in developed countries [2]. An estimated 85,500 cases of HIV and hepatitis are contracted by obstetrical/gynecological providers every year, and 90% of those cases are the result of treating patients living in poverty. SurgiBox aims to address these issues by providing a portable, sterile operating environment for use in austere settings. Not only are patients protected from environmental hazards through the use of SurgiBox, but medical personnel are also shielded from patient fluids, blood, and aerosols. SurgiBox consists of a clear, disposable plastic enclosure that is adhered to the patient&amp;apos;s surgical site and inflated with filtered air. Long gloves, similar those used in a glovebox, are integrated into the enclosure and used by the medical personnel to perform the surgery. Surgical instruments are sterilized before the surgery and are placed inside the enclosure prior to the procedure, but materials, or even a baby in the case of a cesarean section, can be passed in or out of the sterile field during the procedure through a resealable port. Particle count testing inside the enclosure shows that particle counts could be maintained at less than 25% of operating room standards for particles greater than 0.5 microns (OR standard: less than 83,000 particles/m3)and 0.3 microns (OR standard: less than 1,000,000 particles/m 3 ).&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>