<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T04:33:34Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/115657" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/115657</identifier><datestamp>2022-01-13T07:54:05Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Brian W. Anthony and Caroline Bjune.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Berringer, Molly A</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2018-05-23T16:29:00Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2018-05-23T16:29:00Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2018</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2018</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/115657</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">1036985370</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2018.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 103-105).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Due to improvements in electronics manufacturing, electronic implants keep decreasing in size and are moving towards integrated-circuit (IC) based designs. As implant electronics become significantly smaller with the use of ICs, traditional implant packaging become a limiting factor on implant miniaturization. Additionally, current packaging techniques can be expensive, and time and labor intensive. Building electronic packages can require many materials, multiple machines, and several manufacturing steps. This thesis explores cold spray as an alternative packaging method that would address the issues associated with traditional packaging. Cold spray could be used to create conformal packaging around electronic implants. Two biocompatible packaging materials, ultra high molecular weight polyethylene (UHMWPE) and titanium, were cold sprayed on two different electronic material substrates, silicon and polyimide. The results from these experiments are presented in this work.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Molly A. Berringer.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">105 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Using cold spray to package electronic implants</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="4ee91b1f-d80e-43ed-813d-931a5153089a">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Using cold spray to package electronic implants&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2018&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Berringer, Molly A&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Due to improvements in electronics manufacturing, electronic implants keep decreasing in size and are moving towards integrated-circuit (IC) based designs. As implant electronics become significantly smaller with the use of ICs, traditional implant packaging become a limiting factor on implant miniaturization. Additionally, current packaging techniques can be expensive, and time and labor intensive. Building electronic packages can require many materials, multiple machines, and several manufacturing steps. This thesis explores cold spray as an alternative packaging method that would address the issues associated with traditional packaging. Cold spray could be used to create conformal packaging around electronic implants. Two biocompatible packaging materials, ultra high molecular weight polyethylene (UHMWPE) and titanium, were cold sprayed on two different electronic material substrates, silicon and polyimide. The results from these experiments are presented in this work.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>