<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T04:48:15Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/117318" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/117318</identifier><datestamp>2022-10-06T17:02:21Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Thomas Heldt.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Imaduddin, Syed M. (Syed Muhammad)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2018-08-08T19:49:08Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2018-08-08T19:49:08Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2018</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2018</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/117318</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">1046086564</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2018.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from student-submitted PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 97-100).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">A noninvasive intracranial pressure (ICP) estimation method is proposed that incorporates model-based estimation within a probabilistic framework. A first-order subject-specific model of the cerebral vasculature relates arterial blood pressure with cerebral blood flow velocity. The model is solved for a range of physiologically plausible ICP values, and the resulting residual errors are transformed into likelihoods for each candidate ICP. The likelihoods are combined with a imulti-modal prior distribution of the ICP to yield an a posteriori distribution whose mode is taken as the final ICP estimate. An extension to this method is proposed to harness the temporal evolution of past ICP estimates for reducing dependence on the multi-modal prior distribution. This approach combines ICP estimates computed with a uniform prior belief with predictions from a single-state model of cerebral autoregulatory dynamics. This method was tested on data from thirteen patients from Boston Children's Hospital and yielded an ICP estimation bias (mean error or accuracy) of 0.3 nrmmHg and a root-mean-squared error (or precision) of 5.2 minHg. These performance characteristics are well within the acceptable range for clinical decision making. The method proposed here therefore constitutes a significant step towards robust, continuous, patient-specific noninvasive ICP determination.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Syed M. Imaduddin.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">100 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">A pseudo-Bayesian model-based approach for noninvasive intracranial pressure estimation</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="767b086f-4c5f-497a-92d7-3166fa668c77">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>A pseudo-Bayesian model-based approach for noninvasive intracranial pressure estimation&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2018&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Imaduddin, Syed M. (Syed Muhammad)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
   	&lt;Abstract>A noninvasive intracranial pressure (ICP) estimation method is proposed that incorporates model-based estimation within a probabilistic framework. A first-order subject-specific model of the cerebral vasculature relates arterial blood pressure with cerebral blood flow velocity. The model is solved for a range of physiologically plausible ICP values, and the resulting residual errors are transformed into likelihoods for each candidate ICP. The likelihoods are combined with a imulti-modal prior distribution of the ICP to yield an a posteriori distribution whose mode is taken as the final ICP estimate. An extension to this method is proposed to harness the temporal evolution of past ICP estimates for reducing dependence on the multi-modal prior distribution. This approach combines ICP estimates computed with a uniform prior belief with predictions from a single-state model of cerebral autoregulatory dynamics. This method was tested on data from thirteen patients from Boston Children&amp;apos;s Hospital and yielded an ICP estimation bias (mean error or accuracy) of 0.3 nrmmHg and a root-mean-squared error (or precision) of 5.2 minHg. These performance characteristics are well within the acceptable range for clinical decision making. The method proposed here therefore constitutes a significant step towards robust, continuous, patient-specific noninvasive ICP determination.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>