<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T17:53:33Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/118696" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/118696</identifier><datestamp>2022-01-13T07:53:53Z</datestamp><setSpec>com_1721.1_97716</setSpec><setSpec>com_1721.1_7749</setSpec><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_97717</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Leslie Norford.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Anderson, Abigail M</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Architecture.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Architecture</dim:field>
   <dim:field mdschema="dc" element="coverage" qualifier="spatial" lang="en_US">d------</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2018-10-22T18:45:19Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2018-10-22T18:45:19Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2018</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2018</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/118696</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">1056959129</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.B., Massachusetts Institute of Technology, Department of Architecture, 2018.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 55-56).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Contaminated particles in hospitals can spread from infected patients to those who are hospitalized for non-disease-related reasons. The reputation of hospitals, especially in the developing world, as places where diseases are spread rather than cured necessitates design strategies focused on stopping or controlling disease spread among patients. In this thesis, I examine the potential of architectural layout, among other factors, to reduce the spread of contaminants through passive ventilation strategies. Using Computational Fluid Dynamics, I propose a system of hospital rooms which minimizes contaminant spread among patients while maintaining comfortable airflow rates.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Abigail M. Anderson.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">58 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Architecture.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Design for infectious disease control in the developing world : the power of natural ventilation</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Power of natural ventilation</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="800dd728-b2fc-4745-9bc6-c5160635c943">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Design for infectious disease control in the developing world : the power of natural ventilation&lt;/Title>
   	&lt;Subtitle>Power of natural ventilation&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2018&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Anderson, Abigail M&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Architecture.&lt;/Keyword>
   	&lt;Abstract>Contaminated particles in hospitals can spread from infected patients to those who are hospitalized for non-disease-related reasons. The reputation of hospitals, especially in the developing world, as places where diseases are spread rather than cured necessitates design strategies focused on stopping or controlling disease spread among patients. In this thesis, I examine the potential of architectural layout, among other factors, to reduce the spread of contaminants through passive ventilation strategies. Using Computational Fluid Dynamics, I propose a system of hospital rooms which minimizes contaminant spread among patients while maintaining comfortable airflow rates.&lt;/Abstract>