<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-21T02:39:45Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/122546" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/122546</identifier><datestamp>2021-07-05T14:03:20Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">John V. Guttag and Adrian V. Dalca.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Lewis, Kathleen M.(Kathleen Marie)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2019-10-11T22:11:17Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2019-10-11T22:11:17Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2019</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2019</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/122546</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">1122563949</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2019</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 37-40).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">We introduce SparseVM, a method to register clinical 3D MR scans faster and more accurately than previously possible. Deformable alignment, or registration, of clinical scans is a fundamental task for many medical image applications such as longitudinal population studies. Most registration algorithms are designed for high-resolution research-quality scans, and under-perform when applied to clinical data. Clinical scans present unique challenges because, in contrast to research-quality scans, clinical scans are often sparse, missing up to 85% of the slices available in research scans. We build on a state-of-the-art learning-based registration method to improve the accuracy of sparse clinical image registration. We evaluate our method on both a clinically-acquired MRI dataset of stroke patients, and on a simulated sparse clinical scan dataset. SparseVM registers MR scans in under a second on a GPU, which is over 1000 x faster than the most accurate clinical registration methods, without compromising accuracy. SparseVM has statistically significant improvements in runtimes over all baselines, and a statistically significant improvement in accuracy over the fastest baseline. Because of these contributions, SparseVM enables clinical analyses that were not previously possible. Our code is publicly available at voxelmorph. mit . edu.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Kathleen M. Lewis.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="collection" lang="en_US">S.M. Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">40 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Fast learning-based registration of sparse 3D clinical images</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Fast learning-based registration of sparse three-dimensional clinical images</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="imported" lang="en_US">2019-10-11T22:11:16Z</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree" lang="en_US">Master</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="department" lang="en_US">EECS</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="755ee711-4d91-43c8-b187-1b64f12f7139">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Fast learning-based registration of sparse 3D clinical images&lt;/Title>
   	&lt;Subtitle>Fast learning-based registration of sparse three-dimensional clinical images&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2019&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Lewis, Kathleen M.(Kathleen Marie)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
   	&lt;Abstract>We introduce SparseVM, a method to register clinical 3D MR scans faster and more accurately than previously possible. Deformable alignment, or registration, of clinical scans is a fundamental task for many medical image applications such as longitudinal population studies. Most registration algorithms are designed for high-resolution research-quality scans, and under-perform when applied to clinical data. Clinical scans present unique challenges because, in contrast to research-quality scans, clinical scans are often sparse, missing up to 85% of the slices available in research scans. We build on a state-of-the-art learning-based registration method to improve the accuracy of sparse clinical image registration. We evaluate our method on both a clinically-acquired MRI dataset of stroke patients, and on a simulated sparse clinical scan dataset. SparseVM registers MR scans in under a second on a GPU, which is over 1000 x faster than the most accurate clinical registration methods, without compromising accuracy. SparseVM has statistically significant improvements in runtimes over all baselines, and a statistically significant improvement in accuracy over the fastest baseline. Because of these contributions, SparseVM enables clinical analyses that were not previously possible. Our code is publicly available at voxelmorph. mit . edu.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>