<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T21:46:42Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/123050" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/123050</identifier><datestamp>2026-06-06T00:55:19Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Charles G. Sodini and Carlos Segura.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">McCuen, Scott Matthew.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2019-11-22T00:04:21Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2019-11-22T00:04:21Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2019</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2019</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/123050</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">1128022735</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, 2019</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from student-submitted PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 45-46).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Neuromodulation is a promising treatment for a variety of otherwise intractable medical conditions. Current neuromodulation devices are large, single-purpose, and limited in functionality. Draper developed a novel, implantable neuromodulation system to address these shortcomings. The system is wireless and networked, and it consists of one external transceiver and multiple implants. The primary contributions of this project included demonstration of stimulation with an implant through a wired interface, demonstration and characterization of a Bluetooth Low Energy (BLE) connection with an implant, and demonstration of stimulation on an implant from a command sent through BLE. The primary challenges of the project were to understand, debug, and validate a complex embedded system. When evaluating BLE performance, a BLE connection interval of 10ms led to a mean latency of 21.2ms with a standard deviation of 6.9ms. The BLE hardware consumed 0.66mW when idle and 3.5mW when connected.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Scott Matthew McCuen.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.Eng.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="collection" lang="en_US">M.Eng. Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">46 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">A wireless communication link for a miniature, implantable neuromodulation system</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="imported" lang="en_US">2019-11-22T00:04:20Z</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree" lang="en_US">Master</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="department" lang="en_US">EECS</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="9fb27faa-8ee9-4023-bbd4-fb44e415c0ab">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>A wireless communication link for a miniature, implantable neuromodulation system&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2019&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>McCuen, Scott Matthew.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
   	&lt;Abstract>Neuromodulation is a promising treatment for a variety of otherwise intractable medical conditions. Current neuromodulation devices are large, single-purpose, and limited in functionality. Draper developed a novel, implantable neuromodulation system to address these shortcomings. The system is wireless and networked, and it consists of one external transceiver and multiple implants. The primary contributions of this project included demonstration of stimulation with an implant through a wired interface, demonstration and characterization of a Bluetooth Low Energy (BLE) connection with an implant, and demonstration of stimulation on an implant from a command sent through BLE. The primary challenges of the project were to understand, debug, and validate a complex embedded system. When evaluating BLE performance, a BLE connection interval of 10ms led to a mean latency of 21.2ms with a standard deviation of 6.9ms. The BLE hardware consumed 0.66mW when idle and 3.5mW when connected.&lt;/Abstract&gt;
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>