<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T17:17:18Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/126993" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/126993</identifier><datestamp>2021-07-05T14:03:20Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">James L. Kirtley, Jr. and Georgia Perakis.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Alrayes, Ali Said.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Sloan School of Management.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Leaders for Manufacturing Program.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Sloan School of Management</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Leaders for Manufacturing Program</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2020-09-03T17:16:25Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2020-09-03T17:16:25Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2020</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2020</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/126993</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">1191618530</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: M.B.A., Massachusetts Institute of Technology, Sloan School of Management, in conjunction with the Leaders for Manufacturing Program at MIT, May, 2020</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, in conjunction with the Leaders for Manufacturing Program at MIT, 2020</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from the official PDF of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 63-65).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The objective of this project is to demonstrate the technical ability and cost-effectiveness of reducing electric transmission system overvoltage violations using distributed generation (DG) smart inverters connected to the electric distribution system. Overvoltage violations are situations when the system exhibits voltage levels outside of the acceptable range set by the American National Standards Institute (ANSI) of 105% of nominal system voltage. The challenge that Atlantic Electric could potentially face from the rapid deployment of DG across its distribution system - driven by new additional renewable energy incentive programs in the US State in which it operates - is the underloading of its high voltage (69kV and 115kV) transmission lines causing overvoltage violations at the ends of the transmission lines. The traditional response to this challenge is to install system upgrades on the transmission system in the form of shunt reactors.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">However, these system upgrades are expensive and time-consuming to install, which could de-incentivize and delay the deployment of DG projects. The solution we propose is to utilize the reactive power absorption capability of the DG inverters to absorb excessive reactive power from the transmission system. In this work, we investigate feeders' maximum capability of reactive power absorption through distributed generation (DG) smart inverters by modeling two "representative" Atlantic Electric distribution feeders under different PV deployment scenarios based on the feeders' load and generation levels, among other factors. We then perform a cost-benefit analysis to compare against installing shunt reactors. Our findings show that implementing an inverter-based solution has a range of significant cost-savings of up to $300,000/year when compared with installing shunt reactors on the transmission system.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">This arrangement, however, is one that hinges on the utility's ability to review regulatory and commercial with all stakeholders involved.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Ali Said Alrayes.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.B.A.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="collection" lang="en_US">M.B.A. Massachusetts Institute of Technology, Sloan School of Management</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="collection" lang="en_US">S.M. Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">65 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Sloan School of Management.</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Leaders for Manufacturing Program.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Transmission system overvoltage mitigation through the use of distributed generation (DG) smart inverters</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="imported" lang="en_US">2020-09-03T17:16:25Z</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree" lang="en_US">Master</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="department" lang="en_US">Sloan</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="department" lang="en_US">EECS</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="566fd6ff-27c7-4abc-b5db-d5997e99e691">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Transmission system overvoltage mitigation through the use of distributed generation (DG) smart inverters&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2020&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Alrayes, Ali Said.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Sloan School of Management.&lt;/Keyword>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
    &lt;Keyword>Leaders for Manufacturing Program.&lt;/Keyword>
   	&lt;Abstract>The objective of this project is to demonstrate the technical ability and cost-effectiveness of reducing electric transmission system overvoltage violations using distributed generation (DG) smart inverters connected to the electric distribution system. Overvoltage violations are situations when the system exhibits voltage levels outside of the acceptable range set by the American National Standards Institute (ANSI) of 105% of nominal system voltage. The challenge that Atlantic Electric could potentially face from the rapid deployment of DG across its distribution system - driven by new additional renewable energy incentive programs in the US State in which it operates - is the underloading of its high voltage (69kV and 115kV) transmission lines causing overvoltage violations at the ends of the transmission lines. The traditional response to this challenge is to install system upgrades on the transmission system in the form of shunt reactors.&lt;/Abstract>
   	&lt;Abstract>However, these system upgrades are expensive and time-consuming to install, which could de-incentivize and delay the deployment of DG projects. The solution we propose is to utilize the reactive power absorption capability of the DG inverters to absorb excessive reactive power from the transmission system. In this work, we investigate feeders&amp;apos; maximum capability of reactive power absorption through distributed generation (DG) smart inverters by modeling two &amp;quot;representative&amp;quot; Atlantic Electric distribution feeders under different PV deployment scenarios based on the feeders&amp;apos; load and generation levels, among other factors. We then perform a cost-benefit analysis to compare against installing shunt reactors. Our findings show that implementing an inverter-based solution has a range of significant cost-savings of up to $300,000/year when compared with installing shunt reactors on the transmission system.&lt;/Abstract>
   	&lt;Abstract>This arrangement, however, is one that hinges on the utility&amp;apos;s ability to review regulatory and commercial with all stakeholders involved.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>