<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T21:17:06Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/127111" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/127111</identifier><datestamp>2021-07-05T14:03:20Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Linda Griffith and Scott Manalis.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Zonis, Raphael Matan.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2020-09-03T17:47:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2020-09-03T17:47:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2020</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2020</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/127111</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">1191836223</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, May, 2020</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from the official PDF of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 98-112).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Oocyte cryopreservation is an assistive reproductive procedure that has allowed women to overcome infertility and enjoy increased reproductive freedom. Despite a rapid increase in oocyte cryopreservation cycles over the past seven years, success rates both between and within clinics remain highly heterogeneous, negatively impacting clinical outcomes. This is because the clinical gold standard in oocyte cryopreservation, manual vitrification, is a technically challenging procedure that's success is strongly dependent on the experience, training, and attentiveness of the operator. In this thesis, the development of an automated platform for the introduction and removal of cryoprotective agents (CPAs) to and from the oocyte is described. By combining microfluidics, automation, and optical measurement systems, the proposed system aims to overcome the challenges inherent to manual vitrification, and improve upon other existing platforms designed to perform these tasks. Development and fabrication of the microfluidic component of this proposed system is described, and is validated through a proof-of-concept experiment. This work marks the first step towards a completely automated vitrification platform, capable of removing the uncertainty in success currently plaguing clinics and their patients.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Raphael Matan Zonis.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="collection" lang="en_US">S.M. Massachusetts Institute of Technology, Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">112 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Development of an automated microfluidic system for the loading and unloading of cryoprotectants from mammalian oocytes</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="imported" lang="en_US">2020-09-03T17:47:24Z</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree" lang="en_US">Master</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="department" lang="en_US">MechE</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="37fac834-f0ec-4ab9-a0dd-8f6b21a917a0">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Development of an automated microfluidic system for the loading and unloading of cryoprotectants from mammalian oocytes&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2020&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Zonis, Raphael Matan.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Oocyte cryopreservation is an assistive reproductive procedure that has allowed women to overcome infertility and enjoy increased reproductive freedom. Despite a rapid increase in oocyte cryopreservation cycles over the past seven years, success rates both between and within clinics remain highly heterogeneous, negatively impacting clinical outcomes. This is because the clinical gold standard in oocyte cryopreservation, manual vitrification, is a technically challenging procedure that&amp;apos;s success is strongly dependent on the experience, training, and attentiveness of the operator. In this thesis, the development of an automated platform for the introduction and removal of cryoprotective agents (CPAs) to and from the oocyte is described. By combining microfluidics, automation, and optical measurement systems, the proposed system aims to overcome the challenges inherent to manual vitrification, and improve upon other existing platforms designed to perform these tasks. Development and fabrication of the microfluidic component of this proposed system is described, and is validated through a proof-of-concept experiment. This work marks the first step towards a completely automated vitrification platform, capable of removing the uncertainty in success currently plaguing clinics and their patients.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>