<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T03:48:37Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/127917" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/127917</identifier><datestamp>2021-07-05T14:03:20Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Alexander H. Slocum.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Flores, Ryan Maximiliano.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2020-10-08T21:30:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2020-10-08T21:30:18Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2020</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2020</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/127917</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">1197727845</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, May, 2020</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from the official PDF of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 61-62).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The process of unit dose continuous lyophilization consists of moving vials containing unit doses of pharmaceutical product though a series of process chambers with varying pressures and temperatures. In order to move the vials between process chambers with varying pressures without disturbing the conditions within each respective chamber, a load lock is required. Although load locks are commonly used in the semiconductor industry, existing designs are not directly applicable to the unit dose continuous lyophilization process due to the unique geometric constraints on the system. This thesis document details the design of a load-lock door for the unit dose continuous lyophilization process. To meet the load-lock door functional requirements, a four-bar linkage load-lock door and a load-lock door with ground pivots offset from the sealing surface were designed. Because the driving performance parameters cannot be reliably modeled, the seal performance, particle generation, and seal adhesion of each design will be experimentally tested. The highest performing design will be chosen and improved based on the experimental results.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Ryan Maximiliano Flores.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="collection" lang="en_US">S.B. Massachusetts Institute of Technology, Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">62 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Design of load-lock door for unit dose continuous lyophilization process for complex biologics</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="imported" lang="en_US">2020-10-08T21:30:17Z</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree" lang="en_US">Bachelor</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="department" lang="en_US">MechE</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="8cdf29e1-063b-4d76-b718-64b229d7381e">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Design of load-lock door for unit dose continuous lyophilization process for complex biologics&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2020&lt;/PublicationDate>
   	&lt;Authors&gt;
      	&lt;Author>
        	&lt;DisplayName>Flores, Ryan Maximiliano.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>The process of unit dose continuous lyophilization consists of moving vials containing unit doses of pharmaceutical product though a series of process chambers with varying pressures and temperatures. In order to move the vials between process chambers with varying pressures without disturbing the conditions within each respective chamber, a load lock is required. Although load locks are commonly used in the semiconductor industry, existing designs are not directly applicable to the unit dose continuous lyophilization process due to the unique geometric constraints on the system. This thesis document details the design of a load-lock door for the unit dose continuous lyophilization process. To meet the load-lock door functional requirements, a four-bar linkage load-lock door and a load-lock door with ground pivots offset from the sealing surface were designed. Because the driving performance parameters cannot be reliably modeled, the seal performance, particle generation, and seal adhesion of each design will be experimentally tested. The highest performing design will be chosen and improved based on the experimental results.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>