<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-11-29T21:24:55Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/129183" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/129183</identifier><datestamp>2025-12-17T03:56:52Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Joel Voldman.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Liao, Wei,S.M.Massachusetts Institute of Technology.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2021-01-06T18:33:09Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2021-01-06T18:33:09Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2020</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2020</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/129183</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">1227278359</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, September, 2020</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from student-submitted PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (pages 97-105).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Microfluidic Organs-on-chips (OOC) technology hold great promise for advancing the understanding of blood-brain-barrier (BBB) physiology and investigating BBB dysfunction in central nervous system diseases. It can provide high physiological relevance through engineering a range of system parameters. However, the resulting system can be hard to operate, have inadequate robustness and limited throughput, which is a major challenge that must be overcome before its widespread acceptance by both basic and applied research area. This thesis proposed a system which is aimed at solving this particular challenge of microfluidic OOC systems by having the open-well design to ease the process of liquid handling and allows facile assay while maintaining the high biological sophistication it can model for the BBB (microarchitecture, vascular perfusion etc.). A simulation model was developed to optimize the device design and predict the distribution of one vital chemical stimulating signal for vasculogenesis -- Vascular Endothelial Growth Factor (VEGF), where distinctive isoform-specific transport profiles were found due to the binding reaction with the extracellular matrix (ECM). Experimental validation was performed to examine the ECM-binding capability for a specific isoform, which yielded consistent results with the simulation. Next, preliminary experiments for the proposed system were conducted, which include the vasculogenesis assay using brain endothelial cells derived from induced pluripotent stem cells (iPSCs) and the APTES-mediated polystyrene-PDMS bonding. These two aspects are integral for the next-stage development of the proposed system and the implementation of a multicellular BBB model on this platform. It is anticipated that the proposed system will realize facile, robust and high-throughput assays thus wider adoption in biology research area.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Wei Liao.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="collection" lang="en_US">S.M. Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">105 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">en</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">An open-well organs-on-chips device for engineering the blood-brain-barrier</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Open-well OOC device for engineering the BBB</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="relation" qualifier="orgunit" lang="en_US">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="imported" lang="en_US">2021-01-06T18:33:08Z</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree" lang="en_US">Master</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="department" lang="en_US">EECS</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="7ea9cd1f-ed04-4540-b837-032cff908eb9">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en&lt;/Language>
   	&lt;Title>An open-well organs-on-chips device for engineering the blood-brain-barrier&lt;/Title>
   	&lt;Subtitle>Open-well OOC device for engineering the BBB&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2020&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Liao, Wei,S.M.Massachusetts Institute of Technology.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
   	&lt;Abstract>Microfluidic Organs-on-chips (OOC) technology hold great promise for advancing the understanding of blood-brain-barrier (BBB) physiology and investigating BBB dysfunction in central nervous system diseases. It can provide high physiological relevance through engineering a range of system parameters. However, the resulting system can be hard to operate, have inadequate robustness and limited throughput, which is a major challenge that must be overcome before its widespread acceptance by both basic and applied research area. This thesis proposed a system which is aimed at solving this particular challenge of microfluidic OOC systems by having the open-well design to ease the process of liquid handling and allows facile assay while maintaining the high biological sophistication it can model for the BBB (microarchitecture, vascular perfusion etc.). A simulation model was developed to optimize the device design and predict the distribution of one vital chemical stimulating signal for vasculogenesis -- Vascular Endothelial Growth Factor (VEGF), where distinctive isoform-specific transport profiles were found due to the binding reaction with the extracellular matrix (ECM). Experimental validation was performed to examine the ECM-binding capability for a specific isoform, which yielded consistent results with the simulation. Next, preliminary experiments for the proposed system were conducted, which include the vasculogenesis assay using brain endothelial cells derived from induced pluripotent stem cells (iPSCs) and the APTES-mediated polystyrene-PDMS bonding. These two aspects are integral for the next-stage development of the proposed system and the implementation of a multicellular BBB model on this platform. It is anticipated that the proposed system will realize facile, robust and high-throughput assays thus wider adoption in biology research area.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>