<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-23T06:38:15Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/130604" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/130604</identifier><datestamp>2021-07-05T14:03:20Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Pattie Maes.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Pataranutaporn, Pat.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Program in Media Arts and Sciences (Massachusetts Institute of Technology)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Program in Media Arts and Sciences (Massachusetts Institute of Technology)</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2021-05-14T16:28:34Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2021-05-14T16:28:34Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2020</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2020</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/130604</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">1249702761</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis: S.M., Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences, September, 2020</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Cataloged from the official PDF version of thesis.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">We explore the vision of closed-loop bio-digital interfaces for human augmentation, where the bio-digital system allows for both sensing and writing biological information to the body. Current-generation wearable devices sense an individual's physiological data such as heart rate, respiration, electrodermal activity, and EEG, but lack in sensing their biological counterparts, which drive the majority of individual's physiological signals. On the other hand, biosensors for detecting biochemical markers are currently limited to one-time use, are non-continuous and don't provide flexibility in choosing which biomarker they sense. We believe that the future for wearable biosensors lies in going beyond specific sensing capabilities and becoming a wearable "lab" on body, where a small device can offer a fully integrated and re-configurable system that mimics several processes usually performed in the laboratory for clinical diagnostics and analysis of human health. To illustrate our vision of having a lab on body, we prototyped "Wearable Lab" a bio-digital platform for sensing biochemical and digital data from saliva. Our platform contains digital sensors such as an IMU for activity recognition, as well as an automated system for continuous sampling of biomarkers from saliva by leveraging existing paper-based biochemical sensors. The platform could aid with longitudinal studies of biomarkers and early diagnosis of diseases. We present example data collected from the device, show a preliminary evaluation, and discuss the limitation of our platform.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Pat Pataranutaporn.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="collection" lang="en_US">S.M. Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">124 pages</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Program in Media Arts and Sciences</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Wearable Lab and BioFab on body : towards closed-loop bio-digital human augmentation</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Towards closed-loop bio-digital human augmentation</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="imported" lang="en_US">2021-05-14T16:28:34Z</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree" lang="en_US">Master</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="department" lang="en_US">Media</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="91cb4f5c-f538-441e-99f5-b9dc02991987">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Wearable Lab and BioFab on body : towards closed-loop bio-digital human augmentation&lt;/Title>
   	&lt;Subtitle>Towards closed-loop bio-digital human augmentation&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2020&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Pataranutaporn, Pat.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Program in Media Arts and Sciences&lt;/Keyword>
   	&lt;Abstract>We explore the vision of closed-loop bio-digital interfaces for human augmentation, where the bio-digital system allows for both sensing and writing biological information to the body. Current-generation wearable devices sense an individual&amp;apos;s physiological data such as heart rate, respiration, electrodermal activity, and EEG, but lack in sensing their biological counterparts, which drive the majority of individual&amp;apos;s physiological signals. On the other hand, biosensors for detecting biochemical markers are currently limited to one-time use, are non-continuous and don&amp;apos;t provide flexibility in choosing which biomarker they sense. We believe that the future for wearable biosensors lies in going beyond specific sensing capabilities and becoming a wearable &amp;quot;lab&amp;quot; on body, where a small device can offer a fully integrated and re-configurable system that mimics several processes usually performed in the laboratory for clinical diagnostics and analysis of human health. To illustrate our vision of having a lab on body, we prototyped &amp;quot;Wearable Lab&amp;quot; a bio-digital platform for sensing biochemical and digital data from saliva. Our platform contains digital sensors such as an IMU for activity recognition, as well as an automated system for continuous sampling of biomarkers from saliva by leveraging existing paper-based biochemical sensors. The platform could aid with longitudinal studies of biomarkers and early diagnosis of diseases. We present example data collected from the device, show a preliminary evaluation, and discuss the limitation of our platform.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>