<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T21:57:53Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/144574" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/144574</identifier><datestamp>2022-08-30T03:07:09Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Raman, Ritu</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Thompson, Erik M.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2022-08-29T15:56:47Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2022-08-29T15:56:47Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2022-05</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2022-06-14T19:35:42.123Z</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/144574</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">A new design for the skeleton of biohybrid robots, millimeter scale soft robots powered by engineered muscle actuators, was developed to provide a binary change in stiffness. Two variations of the design were created, one using elastic 50A resin and the other PDMS. The elastic 50A resin design was fabricated successfully. The design uses a manually placed stiffening beam to create the desired change in stiffness. This would allow for the determination of the effects of training with higher stiffnesses after muscle differentiation. These biohybrid robots provide a test bed for studying engineered skeletal muscle and contribute to potential future applications in tissue engineering and biomechanical devices.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">S.B.</dim:field>
   <dim:field mdschema="dc" element="publisher">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights">In Copyright - Educational Use Permitted</dim:field>
   <dim:field mdschema="dc" element="rights">Copyright retained by author(s)</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">https://rightsstatements.org/page/InC-EDU/1.0/</dim:field>
   <dim:field mdschema="dc" element="title">Manipulating Stiffness of Biomechanical Systems to Train Muscle</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree">Bachelor</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Bachelor of Science in Mechanical Engineering</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="dac7953c-7b92-4315-80e1-b9924b2c2ff8">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
   	&lt;Title>Manipulating Stiffness of Biomechanical Systems to Train Muscle&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2022-05&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Thompson, Erik M.&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>https://rightsstatements.org/page/InC-EDU/1.0/&lt;/License>
   	&lt;Abstract>A new design for the skeleton of biohybrid robots, millimeter scale soft robots powered by engineered muscle actuators, was developed to provide a binary change in stiffness. Two variations of the design were created, one using elastic 50A resin and the other PDMS. The elastic 50A resin design was fabricated successfully. The design uses a manually placed stiffening beam to create the desired change in stiffness. This would allow for the determination of the effects of training with higher stiffnesses after muscle differentiation. These biohybrid robots provide a test bed for studying engineered skeletal muscle and contribute to potential future applications in tissue engineering and biomechanical devices.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>