<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T04:36:01Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/151930" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/151930</identifier><datestamp>2026-07-31T14:59:53Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Kamm, Roger D.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Jia, Delace (Delace L.)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2023-08-23T16:19:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2023-08-23T16:19:50Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2023-06</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2023-07-18T16:17:20.327Z</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/151930</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Microphysiological systems provide novel platforms for drug testing and therapeutic target discovery, through their three-dimensional morphologies that mimic specific tissues and organs. In concurrence with these systems, microfluidic channels allow for a sufficient supply of nutrients to the cell culture; by creating pressure gradients across the system, they allow for fluid flow through the tissue medium. A microfluidic pump, Microheart, for continuous flow through microphysiological systems was presented in Offeddu, 2021. The design introduced a novel, low-cost method of delivering cell culture media at low flow rates. While the Microheart pumps in practice have qualitatively provided an indication of media flow through microphysiological systems, the yield rate of production, and efficacy of their function have not been fully characterized. The following study explores the potential failure modes of the Microheart pump, and characterizes the pump consistency over the standard time of function with cell cultures.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">S.B.</dim:field>
   <dim:field mdschema="dc" element="publisher">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights">In Copyright - Educational Use Permitted</dim:field>
   <dim:field mdschema="dc" element="rights">Copyright retained by author(s)</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">https://rightsstatements.org/page/InC-EDU/1.0/</dim:field>
   <dim:field mdschema="dc" element="title">Characterizing Failure Modes in Continuous Flow Microfluidic Pumps</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree">Bachelor</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Bachelor of Science in Mechanical Engineering</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="2b5bf2f6-79f5-4689-9c92-1904805c78c8">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
   	&lt;Title>Characterizing Failure Modes in Continuous Flow Microfluidic Pumps&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2023-06&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Jia, Delace (Delace L.)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>https://rightsstatements.org/page/InC-EDU/1.0/&lt;/License>
   	&lt;Abstract>Microphysiological systems provide novel platforms for drug testing and therapeutic target discovery, through their three-dimensional morphologies that mimic specific tissues and organs. In concurrence with these systems, microfluidic channels allow for a sufficient supply of nutrients to the cell culture; by creating pressure gradients across the system, they allow for fluid flow through the tissue medium. A microfluidic pump, Microheart, for continuous flow through microphysiological systems was presented in Offeddu, 2021. The design introduced a novel, low-cost method of delivering cell culture media at low flow rates. While the Microheart pumps in practice have qualitatively provided an indication of media flow through microphysiological systems, the yield rate of production, and efficacy of their function have not been fully characterized. The following study explores the potential failure modes of the Microheart pump, and characterizes the pump consistency over the standard time of function with cell cultures.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>