<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-22T04:04:56Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/152718" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/152718</identifier><datestamp>2023-11-03T03:19:16Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Dagdeviren, Canan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Shuvo, Ikra Iftekhar</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Program in Media Arts and Sciences (Massachusetts Institute of Technology)</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2023-11-02T20:10:45Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2023-11-02T20:10:45Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2023-09</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2023-09-14T18:08:47.901Z</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/152718</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="orcid">0000-0002-9667-5170</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Mini electronics in wearables inspired this study. Thus, this work offers a new box-shaped high frequency (7.5 MHz) low aperture 2D phased sparse array ultrasonic transducer developed, built, and characterized. The capacity of matrix or 2D phased arrays to generate ultrasound beams without requiring any form of motion or mechanical steering holds potential value in the biomedical sonographic domain. However, these systems need a large number of piezoelectric elements to sample the active aperture, which is smaller than λ/2 wavelength between them, necessitating the need for a sizable or large transducer. To the best of knowledge, this is the first endeavor to design and microfabricate a 7.5 MHz transducer array, based on commercial PZT-5H polycrystalline materials, as tiny as 70x70 µm per transducer with a pitch of 102 µm to maintain an inter-element separation below 50% of the lambda. The study employs a square box-shaped structure that houses the transmitters and receivers perpendicular to each other, resulting in a reduced aperture and compact design compared to different commercial designs. This transducer not only provides satisfactory longitudinal k33 coefficient (0.45-0.5), acoustic pressure (2.1 kPa), sound pressure level (180 dB), low Q-factor (1.19), thermal stability, and high bandwidth (5.6 MHz, 73.41%), while minimizing cross-talk (&lt;-50 dB), but also reduces the overall transducer area due to its unique sparse array configuration, resulting in a diminutive size (3.3 mm x 3.3 mm).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">S.M.</dim:field>
   <dim:field mdschema="dc" element="publisher">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights">In Copyright - Educational Use Permitted</dim:field>
   <dim:field mdschema="dc" element="rights">Copyright retained by author(s)</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">https://rightsstatements.org/page/InC-EDU/1.0/</dim:field>
   <dim:field mdschema="dc" element="title">Microfabrication and characterization of a new box-shaped high frequency (7.5 MHz) low aperture 2D phased ultrasound transducer array</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree">Master</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Master of Science in Media Arts and Sciences</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="b9fadb1b-168d-46c6-93e1-bd6ccdb37fc9">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
   	&lt;Title>Microfabrication and characterization of a new box-shaped high frequency (7.5 MHz) low aperture 2D phased ultrasound transducer array&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2023-09&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Shuvo, Ikra Iftekhar&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>https://rightsstatements.org/page/InC-EDU/1.0/&lt;/License>
   	&lt;Abstract>Mini electronics in wearables inspired this study. Thus, this work offers a new box-shaped high frequency (7.5 MHz) low aperture 2D phased sparse array ultrasonic transducer developed, built, and characterized. The capacity of matrix or 2D phased arrays to generate ultrasound beams without requiring any form of motion or mechanical steering holds potential value in the biomedical sonographic domain. However, these systems need a large number of piezoelectric elements to sample the active aperture, which is smaller than λ/2 wavelength between them, necessitating the need for a sizable or large transducer. To the best of knowledge, this is the first endeavor to design and microfabricate a 7.5 MHz transducer array, based on commercial PZT-5H polycrystalline materials, as tiny as 70x70 µm per transducer with a pitch of 102 µm to maintain an inter-element separation below 50% of the lambda. The study employs a square box-shaped structure that houses the transmitters and receivers perpendicular to each other, resulting in a reduced aperture and compact design compared to different commercial designs. This transducer not only provides satisfactory longitudinal k33 coefficient (0.45-0.5), acoustic pressure (2.1 kPa), sound pressure level (180 dB), low Q-factor (1.19), thermal stability, and high bandwidth (5.6 MHz, 73.41%), while minimizing cross-talk (&amp;lt;-50 dB), but also reduces the overall transducer area due to its unique sparse array configuration, resulting in a diminutive size (3.3 mm x 3.3 mm).&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>