<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T13:10:54Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/155317" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/155317</identifier><datestamp>2024-06-28T03:51:02Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Tibbits, Skylar</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Roche, Ellen</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Chen, Sophia</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Architecture</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2024-06-27T19:44:25Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2024-06-27T19:44:25Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2024-05</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2023-07-17T14:35:36.950Z</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/155317</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Hand osteoarthritis (HOA) is one of the most common forms of arthritis, resulting in pain, aching, stiffness, and inflammation of the joints. One method of alleviating these symptoms is the use of compression gloves, which promote circulation in the hands. However, conventional compression gloves pose several user-based challenges: they are difficult to don/doff; only apply static pressure; and can be uncomfortable, thereby disincentivizing use. Introducing dynamic, shape changing behavior to compression gloves through the use of pneumatics can provide a promising alternative to these limited, conventional forms. Moreover, a pneumatic system allows for high levels of compression that are instantaneous and adjustable. This work explores the design of a pneumatically-actuated adjustable compression glove. The prototype is defined through user needs and is validated through compression testing, successfully and repeatedly producing pressure levels beyond the 3.73 kPa goal defined for HOA in the finger joints.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">S.B.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">S.B.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">S.B.</dim:field>
   <dim:field mdschema="dc" element="publisher">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights">In Copyright - Educational Use Permitted</dim:field>
   <dim:field mdschema="dc" element="rights">Copyright retained by author(s)</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">https://rightsstatements.org/page/InC-EDU/1.0/</dim:field>
   <dim:field mdschema="dc" element="title">Design of an Adjustable Compression Glove for Hand Arthritis</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree">Bachelor</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Bachelor of Science in Art and Design</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Bachelor of Science in Art and Design</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Bachelor of Science in Engineering</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="31a011f2-d482-4b87-a574-17bfbf455bdf">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
   	&lt;Title>Design of an Adjustable Compression Glove for Hand Arthritis&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2024-05&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Chen, Sophia&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>https://rightsstatements.org/page/InC-EDU/1.0/&lt;/License>
   	&lt;Abstract>Hand osteoarthritis (HOA) is one of the most common forms of arthritis, resulting in pain, aching, stiffness, and inflammation of the joints. One method of alleviating these symptoms is the use of compression gloves, which promote circulation in the hands. However, conventional compression gloves pose several user-based challenges: they are difficult to don/doff; only apply static pressure; and can be uncomfortable, thereby disincentivizing use. Introducing dynamic, shape changing behavior to compression gloves through the use of pneumatics can provide a promising alternative to these limited, conventional forms. Moreover, a pneumatic system allows for high levels of compression that are instantaneous and adjustable. This work explores the design of a pneumatically-actuated adjustable compression glove. The prototype is defined through user needs and is validated through compression testing, successfully and repeatedly producing pressure levels beyond the 3.73 kPa goal defined for HOA in the finger joints.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication&gt;