<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T14:14:31Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/157727" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/157727</identifier><datestamp>2024-12-03T03:14:20Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">Dagdeviren, Canan</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Du, Wenya</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Program in Media Arts and Sciences (Massachusetts Institute of Technology)</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2024-12-02T21:15:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2024-12-02T21:15:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2024-09</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2024-11-19T19:12:29.227Z</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/157727</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Ultrasound is widely used in clinical practice because it is safe, non-invasive, non-ionizing, low-cost, and provides real-time imaging, monitoring, and therapy. However, conventional ultrasound probes are rigid, pressure-required, and operator-dependent. Replacing rigid transducers with conformable ultrasound transducer arrays can allow image acquisition on curved body parts, improve image quality, and enable functions such as long-term monitoring. In this thesis, I propose a conformable ultrasound breast patch (cUSBr-Patch) consisting of a one-dimensional (1D) phased array and a nature-inspired patch design, which offers large-area, deep tissue scanning and multi-angle, repeatable breast imaging while avoiding the drawbacks of conventional ultrasound imaging technologies. I used a Yb/Bi-doped PIN-PMN-PT single crystal as the active element due to its superior piezoelectric properties (d33 = 2,800 pC/N, εr = 7,000, k33 = 0.93). I then fabricated a 1D phased array transducer consisting of 64 elements with an operational frequency of 7.0 MHz. The 1D array exhibits promising acoustic performance with i) a maximum imaging depth of 80 mm, ii) contrast sensitivity of 3 dB, iii) axial/lateral resolutions of 0.25/1.0 mm at 30 mm depth, and iv) a larger field of view than the commercial handheld linear probe at depths of approximately 30 mm or deeper, indicating a potential reliable capability to detect early-stage breast tumors. Beyond this, comprehensive in vitro experimental studies establish that the cUSBr-Patch can provide accurate and reproducible imaging of different phantoms. The clinical trials reveal that the patch exhibits a sufficient contrast resolution (~3 dB) and axial/lateral resolutions of 0.25/1.0 mm at 30 mm depth, allowing the observation of small cysts (~ 0.3 cm) in the breast. This research develops a first-of-its-kind ultrasound technology for breast tissue scanning and imaging which offers a non-invasive method for tracking real-time dynamic changes of soft tissue.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">S.M.</dim:field>
   <dim:field mdschema="dc" element="publisher">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights">In Copyright - Educational Use Permitted</dim:field>
   <dim:field mdschema="dc" element="rights">Copyright retained by author(s)</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">https://rightsstatements.org/page/InC-EDU/1.0/</dim:field>
   <dim:field mdschema="dc" element="title">Piezoelectric single crystal based one-dimensional phased array for breast tissue imaging</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree">Master</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Master of Science in Media Arts and Sciences</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="c0d593b9-02bb-493d-82d4-d6e946a1ee5f">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
   	&lt;Title>Piezoelectric single crystal based one-dimensional phased array for breast tissue imaging&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2024-09&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Du, Wenya&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>https://rightsstatements.org/page/InC-EDU/1.0/&lt;/License>
   	&lt;Abstract>Ultrasound is widely used in clinical practice because it is safe, non-invasive, non-ionizing, low-cost, and provides real-time imaging, monitoring, and therapy. However, conventional ultrasound probes are rigid, pressure-required, and operator-dependent. Replacing rigid transducers with conformable ultrasound transducer arrays can allow image acquisition on curved body parts, improve image quality, and enable functions such as long-term monitoring. In this thesis, I propose a conformable ultrasound breast patch (cUSBr-Patch) consisting of a one-dimensional (1D) phased array and a nature-inspired patch design, which offers large-area, deep tissue scanning and multi-angle, repeatable breast imaging while avoiding the drawbacks of conventional ultrasound imaging technologies. I used a Yb/Bi-doped PIN-PMN-PT single crystal as the active element due to its superior piezoelectric properties (d33 = 2,800 pC/N, εr = 7,000, k33 = 0.93). I then fabricated a 1D phased array transducer consisting of 64 elements with an operational frequency of 7.0 MHz. The 1D array exhibits promising acoustic performance with i) a maximum imaging depth of 80 mm, ii) contrast sensitivity of 3 dB, iii) axial/lateral resolutions of 0.25/1.0 mm at 30 mm depth, and iv) a larger field of view than the commercial handheld linear probe at depths of approximately 30 mm or deeper, indicating a potential reliable capability to detect early-stage breast tumors. Beyond this, comprehensive in vitro experimental studies establish that the cUSBr-Patch can provide accurate and reproducible imaging of different phantoms. The clinical trials reveal that the patch exhibits a sufficient contrast resolution (~3 dB) and axial/lateral resolutions of 0.25/1.0 mm at 30 mm depth, allowing the observation of small cysts (~ 0.3 cm) in the breast. This research develops a first-of-its-kind ultrasound technology for breast tissue scanning and imaging which offers a non-invasive method for tracking real-time dynamic changes of soft tissue.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>