<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T11:39:42Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/158963" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/158963</identifier><datestamp>2025-04-08T04:53:30Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor">White, Jacob</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author">Arango, Nicolas</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2025-03-27T17:00:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2025-03-27T17:00:52Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued">2025-02</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="submitted">2025-03-04T17:18:58.355Z</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">https://hdl.handle.net/1721.1/158963</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract">Local multicoil ΔB₀ shim arrays enable low-cost, simple to fabricate, and physically small, static magnetic field control in magnetic resonance imaging. The presented thesis will show frameworks for coil current calculation for homogeneity and novel selective excitation applications. As MRI RF coils trend towards repositionable and flexible systems for their ease of use and tight-to-the-patient fit, ΔB₀ shim arrays are left behind for lack of rapid, patient-on-the-table calibration. We show an inverse problem approach with physics-based regularization and adaptation to accelerate calibration by over 50 fold. The numerical tools developed for calibration also proved useful for design to enable novel upper bounds on ΔB₀ shim performance and new tools for automatic application and anatomy-specific local multicoil array design.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="publisher">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights">In Copyright - Educational Use Permitted</dim:field>
   <dim:field mdschema="dc" element="rights">Copyright retained by author(s)</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">https://rightsstatements.org/page/InC-EDU/1.0/</dim:field>
   <dim:field mdschema="dc" element="title">ΔB₀ Field Control in High Field MRI with Local Multcoil Shim Arrays</dim:field>
   <dim:field mdschema="dc" element="type">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="mit" element="thesis" qualifier="degree">Doctoral</dim:field>
   <dim:field mdschema="thesis" element="degree" qualifier="name">Doctor of Philosophy</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="01313084-e20e-4660-9fd9-1558533d70f9">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
   	&lt;Title>ΔB₀ Field Control in High Field MRI with Local Multcoil Shim Arrays&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2025-02&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Arango, Nicolas&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>https://rightsstatements.org/page/InC-EDU/1.0/&lt;/License>
   	&lt;Abstract>Local multicoil ΔB₀ shim arrays enable low-cost, simple to fabricate, and physically small, static magnetic field control in magnetic resonance imaging. The presented thesis will show frameworks for coil current calculation for homogeneity and novel selective excitation applications. As MRI RF coils trend towards repositionable and flexible systems for their ease of use and tight-to-the-patient fit, ΔB₀ shim arrays are left behind for lack of rapid, patient-on-the-table calibration. We show an inverse problem approach with physics-based regularization and adaptation to accelerate calibration by over 50 fold. The numerical tools developed for calibration also proved useful for design to enable novel upper bounds on ΔB₀ shim performance and new tools for automatic application and anatomy-specific local multicoil array design.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>