<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T01:23:40Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/28530" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/28530</identifier><datestamp>2022-01-13T07:53:48Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Dennis M. Freeman.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Gu, Jianwen Wendy, 1981-</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Biological Engineering Division.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Biological Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2005-09-27T16:50:16Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2005-09-27T16:50:16Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/28530</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">57364218</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (M. Eng.)--Massachusetts Institute of Technology, Biological Engineering Division, 2004.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaf 39).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Dynamic material properties of the isolated mouse tectorial membrane (TM) were quantified by applying sinusoidal shearing forces to the TM with a microfabricated probe (contact area 30 x 30 [micro]m²). Forces in the range 30-300 nN with frequency in the range 10-9000 Hz were applied tangentially to the surfaces of four TM specimens. We found that TM displacement was linear with respect to force. The TM exhibited both elastic and viscous characteristics, with the elastic behavior being more prominent. The elastic and viscous components of TM impedance remained proportional through two decades of frequency. The radial impedance was approximately three times larger than the longitudinal impedance. The point stiffness of the TM increased with frequency when radial forces were applied but showed no trend with frequency for longitudinal forces. Displacement of surrounding tissue decreased as distance from the probe increased. Space constants were on the order of tens of micrometers. These results represent the most detailed shear measurements to date of the isolated TM and are consistent with those obtained using the magnetic bead method [AF00].</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Jianwen Wendy Gu.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.Eng.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">39 leaves</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">1343842 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">1346000 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en_US</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses may be protected by copyright.  Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Biological Engineering Division.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Measuring mechanical properties of the tectorial membrane with a microfabricated probe</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Shear measurements of mouse tectorial membrane using microelectromechanical systems probe</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="e6a83aef-d4a9-4b5d-b7a3-97e384e2c824">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en_US&lt;/Language>
   	&lt;Title>Measuring mechanical properties of the tectorial membrane with a microfabricated probe&lt;/Title>
   	&lt;Subtitle>Shear measurements of mouse tectorial membrane using microelectromechanical systems probe&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2004&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Gu, Jianwen Wendy, 1981-&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Biological Engineering Division.&lt;/Keyword>
   	&lt;Abstract>Dynamic material properties of the isolated mouse tectorial membrane (TM) were quantified by applying sinusoidal shearing forces to the TM with a microfabricated probe (contact area 30 x 30 [micro]m²). Forces in the range 30-300 nN with frequency in the range 10-9000 Hz were applied tangentially to the surfaces of four TM specimens. We found that TM displacement was linear with respect to force. The TM exhibited both elastic and viscous characteristics, with the elastic behavior being more prominent. The elastic and viscous components of TM impedance remained proportional through two decades of frequency. The radial impedance was approximately three times larger than the longitudinal impedance. The point stiffness of the TM increased with frequency when radial forces were applied but showed no trend with frequency for longitudinal forces. Displacement of surrounding tissue decreased as distance from the probe increased. Space constants were on the order of tens of micrometers. These results represent the most detailed shear measurements to date of the isolated TM and are consistent with those obtained using the magnetic bead method [AF00].&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>