<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T14:40:53Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/28623" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/28623</identifier><datestamp>2022-01-13T07:53:48Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Scott R. Manalis.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Levy-Tzedek, Shelly</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Biological Engineering Division.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Biological Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2005-09-27T17:22:23Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2005-09-27T17:22:23Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/28623</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">57569643</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Biological Engineering Division, 2004.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 33-37).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Label-free detection is the detection of biomolecules and their interactions, without the use of a molecule external to the interaction, used as a reporter to indicate presence and/or location. The suspended microchannel resonator offers the opportunity to perform such label-free measurements. The goal of this work is to open new avenues of possible applications for the suspended channel. I introduce the concept of detecting mass subtraction as a new approach, rather than the conventional detection of mass addition. In a model implementation scenario of this approach, a mass-intensifying tag bound to a small ligand molecule will be equilibrated with surface-immobilized receptors, and later displaced by an identical, but label-free, ligand molecule. This approach offers opportunities to extend the sensitivity range of the device, as well as introduces new functionality for it. It enables researchers to follow, label-free, real-time enzymatic reactions, relative affinities of different ligands to a receptor, and presence of small molecules in a solution.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Shelly Levy-Tzedek.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">37 p.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">2843473 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">2845328 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en_US</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">MIT theses may be protected by copyright.  Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Biological Engineering Division.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Biological detection by means of mass reduction in a suspended microchannel resonator</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="cfa4d196-8afc-41fc-8487-865c563d1f8a">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en_US&lt;/Language>
   	&lt;Title>Biological detection by means of mass reduction in a suspended microchannel resonator&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2004&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Levy-Tzedek, Shelly&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Biological Engineering Division.&lt;/Keyword>
   	&lt;Abstract>Label-free detection is the detection of biomolecules and their interactions, without the use of a molecule external to the interaction, used as a reporter to indicate presence and/or location. The suspended microchannel resonator offers the opportunity to perform such label-free measurements. The goal of this work is to open new avenues of possible applications for the suspended channel. I introduce the concept of detecting mass subtraction as a new approach, rather than the conventional detection of mass addition. In a model implementation scenario of this approach, a mass-intensifying tag bound to a small ligand molecule will be equilibrated with surface-immobilized receptors, and later displaced by an identical, but label-free, ligand molecule. This approach offers opportunities to extend the sensitivity range of the device, as well as introduces new functionality for it. It enables researchers to follow, label-free, real-time enzymatic reactions, relative affinities of different ligands to a receptor, and presence of small molecules in a solution.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>