<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T19:46:49Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/28871" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/28871</identifier><datestamp>2022-01-13T07:54:33Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Christine Ortiz.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Domike, Kristin Rebecca, 1981-</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Materials Science and Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Materials Science and Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2005-09-27T18:47:58Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2005-09-27T18:47:58Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/28871</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">60425230</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Materials Science and Engineering, 2004.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Endotracheal tubes (ETs) are used to aid artificial ventilation in millions of medical patients every year and are known to invoke the proliferative phase in the cell linings. The technical objective of this work was to investigate in vitro the interaction between epithelial cells and current poly(vinyl chloride)-based ET materials, as well as some ET samples embedded with materials intended to improve biocompatibility properties of the tubes. Cells were grown in wells with small samples of ETs and proliferation and migration were observed using phase microscopy. ETs appeared to increase cell growth wherever cells came into contact with the material. The cell morphology altered once in contact with the ET sample. Cell growth on and around the ETs with embedded material appeared to slow, but had significant visible changes in cell morphology. The need for continued research in this area of research and development and future steps are addressed. A proposal for starting a company around a safer material for use in endotracheal tubes was developed and showed significant barriers to entry for a small medical device company with a single product. Subsequently, the most appropriate approach for bringing a new ET to the market would be by way of a licensing with an existing manufacturer.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Kristin Rebecca Domike.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.Eng.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">71 leaves</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">4987553 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">4994618 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso">en_US</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Materials Science and Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">The impact of improved materials in poly(vinyl chloride)-based endotracheal tubes</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="22d1de6f-627b-4478-b373-65c5fc1a04ae">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>en_US&lt;/Language>
   	&lt;Title>The impact of improved materials in poly(vinyl chloride)-based endotracheal tubes&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2004&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Domike, Kristin Rebecca, 1981-&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Materials Science and Engineering.&lt;/Keyword>
   	&lt;Abstract>Endotracheal tubes (ETs) are used to aid artificial ventilation in millions of medical patients every year and are known to invoke the proliferative phase in the cell linings. The technical objective of this work was to investigate in vitro the interaction between epithelial cells and current poly(vinyl chloride)-based ET materials, as well as some ET samples embedded with materials intended to improve biocompatibility properties of the tubes. Cells were grown in wells with small samples of ETs and proliferation and migration were observed using phase microscopy. ETs appeared to increase cell growth wherever cells came into contact with the material. The cell morphology altered once in contact with the ET sample. Cell growth on and around the ETs with embedded material appeared to slow, but had significant visible changes in cell morphology. The need for continued research in this area of research and development and future steps are addressed. A proposal for starting a company around a safer material for use in endotracheal tubes was developed and showed significant barriers to entry for a small medical device company with a single product. Subsequently, the most appropriate approach for bringing a new ET to the market would be by way of a licensing with an existing manufacturer.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>