<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T01:47:04Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/30347" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/30347</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Ian W. Hunter.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Crane, Bryan Lee, 1976-</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-03-24T18:42:34Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-03-24T18:42:34Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/30347</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">61134414</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, February 2005.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Page 230 blank.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 181-190).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Real-time polymerase chain reaction (PCR) is the gold-standard for quantitation in both mutation and gene expression analyses. Already this technique has found valuable clinical application in disease diagnosis and progression evaluation. As the number of known gene-disease correlations continues to rise, there will be increased demand for higher throughput and decreased cost for these analyses. Present real-time PCR measurement is based upon the fluorescent intensity of either intercalating dyes or oligonucleotide probes. Intercalating dye methods suffer from a lack of binding specificity, while probe methods are expensive and require increased assay optimization. In this thesis, a new method is presented for monitoring real-time PCR that utilizes the fluorescent anisotropy (FA) of labeled primers. FA, when measured at constant temperature, is indicative of the molecular mass to which the fluorophore is attached. Specificity is improved with the FA method over the use of intercalating dyes since the selective binding of primers is required for signal change. Assay complexity and cost are reduced compared to fluorogenic probe methods since the probes are eliminated. The design of a prototype instrument, which successfully implements this new method, is presented. Instrument and assay performance are compared to intercalating dye assays run in commercially available instrumentation. Theoretical limits on performance are also presented and compared to experimental results. Excellent repeatability and linearity are observed with respect to these benchmarks. This new method, having both high specificity and low optimization complexity, is expected to be particularly applicable to the demanding robustness requirements of nano-scale PCR.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Bryan Lee Crane.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">230 p.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">11755321 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">11785291 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Real time PCR measurement by fluorescence anisotropy</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Polymerase chain reaction measurement by fluorescence anisotropy</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="8db81996-72c7-4e8a-b37a-1ea23504f385">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Real time PCR measurement by fluorescence anisotropy&lt;/Title>
   	&lt;Subtitle>Polymerase chain reaction measurement by fluorescence anisotropy&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2005&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Crane, Bryan Lee, 1976-&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License&gt;
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Real-time polymerase chain reaction (PCR) is the gold-standard for quantitation in both mutation and gene expression analyses. Already this technique has found valuable clinical application in disease diagnosis and progression evaluation. As the number of known gene-disease correlations continues to rise, there will be increased demand for higher throughput and decreased cost for these analyses. Present real-time PCR measurement is based upon the fluorescent intensity of either intercalating dyes or oligonucleotide probes. Intercalating dye methods suffer from a lack of binding specificity, while probe methods are expensive and require increased assay optimization. In this thesis, a new method is presented for monitoring real-time PCR that utilizes the fluorescent anisotropy (FA) of labeled primers. FA, when measured at constant temperature, is indicative of the molecular mass to which the fluorophore is attached. Specificity is improved with the FA method over the use of intercalating dyes since the selective binding of primers is required for signal change. Assay complexity and cost are reduced compared to fluorogenic probe methods since the probes are eliminated. The design of a prototype instrument, which successfully implements this new method, is presented. Instrument and assay performance are compared to intercalating dye assays run in commercially available instrumentation. Theoretical limits on performance are also presented and compared to experimental results. Excellent repeatability and linearity are observed with respect to these benchmarks. This new method, having both high specificity and low optimization complexity, is expected to be particularly applicable to the demanding robustness requirements of nano-scale PCR.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>