<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T19:52:10Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/31131" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/31131</identifier><datestamp>2022-01-13T07:54:23Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Peter Shanahan.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Loux, Brian Michael, 1981-</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Civil and Environmental Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-02-02T18:51:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-02-02T18:51:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/31131</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">61169941</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2005.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaves 60-63).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">An experimental study was carried out to determine the feasibility of an original point of use solar water disinfection system created by the author and named "Spirasol." The study primarily focused on the comparison of microbial removal levels in the Spirasol system and the more traditional solar disinfection method called SODIS that uses a Polyethylene Terephthalate (PET) bottle. To address microbial removal capacity, the two systems were assembled and tested in Nairobi, Kenya and later in Cambridge, Massachusetts. The issue of economic feasibility and component availability were also addressed and factored in heavily during the design phase of the project. The results suggest that the Spirasol system is equally as effective as the traditional SODIS system with respect to microbial inactivation. Analysis of the costs required for continuous and semi-continuous solar disinfection system implied that such systems were not a good match for sites of extreme urban poverty such as the Kibera slum in Nairobi, Kenya. However, the overall low cost among semi-continuous point of use treatment systems and the wide availability of the required pieces made them a sustainable technology for other areas in the developing world where available capital is marginally higher.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Brian Michael Loux.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.Eng.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">77 leaves</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">5410666 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">5418818 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Civil and Environmental Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Spirasol : improvements to semi-continuous solar disinfection water treatment systems</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Improvements to semi-continuous solar disinfection water treatment systems</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="980f2a98-2074-48c8-87cf-05fc910cb9fd">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Spirasol : improvements to semi-continuous solar disinfection water treatment systems&lt;/Title>
   	&lt;Subtitle>Improvements to semi-continuous solar disinfection water treatment systems&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2005&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Loux, Brian Michael, 1981-&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Civil and Environmental Engineering.&lt;/Keyword>
   	&lt;Abstract>An experimental study was carried out to determine the feasibility of an original point of use solar water disinfection system created by the author and named &amp;quot;Spirasol.&amp;quot; The study primarily focused on the comparison of microbial removal levels in the Spirasol system and the more traditional solar disinfection method called SODIS that uses a Polyethylene Terephthalate (PET) bottle. To address microbial removal capacity, the two systems were assembled and tested in Nairobi, Kenya and later in Cambridge, Massachusetts. The issue of economic feasibility and component availability were also addressed and factored in heavily during the design phase of the project. The results suggest that the Spirasol system is equally as effective as the traditional SODIS system with respect to microbial inactivation. Analysis of the costs required for continuous and semi-continuous solar disinfection system implied that such systems were not a good match for sites of extreme urban poverty such as the Kibera slum in Nairobi, Kenya. However, the overall low cost among semi-continuous point of use treatment systems and the wide availability of the required pieces made them a sustainable technology for other areas in the developing world where available capital is marginally higher.&lt;/Abstract>