<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-21T16:01:31Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/32317" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/32317</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Hermano Igo Krebs.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Wheeler, Jason W. (Jason William)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-03-29T18:33:41Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-03-29T18:33:41Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/32317</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">61367272</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2004.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 111-112).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Patients with neurological disorders, such as stroke survivors, can be treated with physical rehabilitation to regain motor control and function. Conventional therapy techniques are labor intensive and non-standardized. This is especially true in gait rehabilitation. The robotic therapy paradigm developed in the Newman Lab for Hu- man Rehabilitation uses low impedance robots, such as the MIT-MANUS, to provide assistive therapy in a repeatable and measurable fashion. A system is now being designed to assist gait rehabilitation using a series of lower extremity and pelvis robots that can be used together or independently. The focus of this document is ankle rehabilitation. Ankle function is typically not targeted in conventional or other robotic therapy systems. The result is often that the patient is required to wear a brace or orthosis after therapy. The proposed module allows all normal ankle movements and is capable of driving the two most important movements in gait, dorsi/plantar flexion and inversion/eversion. It is designed to provide sufficient force to position the foot in swing phase while still being as lightweight and backdriveable as possible. The kinematics consist of two parallel two-link mechanisms. The robot is driven by two DC brushless motors with planetary gearheads to amplify the torque output.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Jason W. Wheeler.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">113, [37] p.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">8121009 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">8128055 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">An ankle robot for a modular gait rehabilitation system</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="15742615-2e54-4232-a046-5cfe80cef36c">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>An ankle robot for a modular gait rehabilitation system&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2004&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName&gt;Wheeler, Jason W. (Jason William)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Patients with neurological disorders, such as stroke survivors, can be treated with physical rehabilitation to regain motor control and function. Conventional therapy techniques are labor intensive and non-standardized. This is especially true in gait rehabilitation. The robotic therapy paradigm developed in the Newman Lab for Hu- man Rehabilitation uses low impedance robots, such as the MIT-MANUS, to provide assistive therapy in a repeatable and measurable fashion. A system is now being designed to assist gait rehabilitation using a series of lower extremity and pelvis robots that can be used together or independently. The focus of this document is ankle rehabilitation. Ankle function is typically not targeted in conventional or other robotic therapy systems. The result is often that the patient is required to wear a brace or orthosis after therapy. The proposed module allows all normal ankle movements and is capable of driving the two most important movements in gait, dorsi/plantar flexion and inversion/eversion. It is designed to provide sufficient force to position the foot in swing phase while still being as lightweight and backdriveable as possible. The kinematics consist of two parallel two-link mechanisms. The robot is driven by two DC brushless motors with planetary gearheads to amplify the torque output.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>