<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T04:42:22Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/32746" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/32746</identifier><datestamp>2022-01-13T07:54:41Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Richard Milner.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Nelson, Justin Matthew, 1981-</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mathematics.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mathematics</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Physics</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-05-15T20:27:03Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-05-15T20:27:03Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/32746</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">56734069</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics; and, (S.B.)--Massachusetts Institute of Technology, Dept. of Mathematics, 2004.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">MIT Institute Archives copy: leaves 2-22 bound in reverse order.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaf 22).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">This study is concerned with the percentage of [gamma]-rays of a certain energy having their energy correctly measured by a high purity Germanium [gamma]-ray detector. The ratio between the total counts and the counts within the energy peak (total-to-peak ratio) is determined for seven energies ranging from 89 keV to 1275 keV. A Monte Carlo based on the physical parameters of the detector was used to extrapolate between these points and after an energy independent scaling factor fit the data with a reduced [chi]² slightly below 1. The same experiment was repeated with a lead brick and then a β detector near the Ge detector and these objects were found to not have an effect on the total-to-peak ratios within the precision of the experiment.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Justin Matthew Nelson.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">22 leaves</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">878708 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">876736 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Physics.</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mathematics.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Total-to-peak ratios of high purity germanium gamma ray detector</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="85d5d21f-67b4-4fe7-9d0d-4094380da20d">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Total-to-peak ratios of high purity germanium gamma ray detector&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2004&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Nelson, Justin Matthew, 1981-&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Physics.&lt;/Keyword>
    &lt;Keyword>Mathematics.&lt;/Keyword>
   	&lt;Abstract>This study is concerned with the percentage of [gamma]-rays of a certain energy having their energy correctly measured by a high purity Germanium [gamma]-ray detector. The ratio between the total counts and the counts within the energy peak (total-to-peak ratio) is determined for seven energies ranging from 89 keV to 1275 keV. A Monte Carlo based on the physical parameters of the detector was used to extrapolate between these points and after an energy independent scaling factor fit the data with a reduced [chi]² slightly below 1. The same experiment was repeated with a lead brick and then a β detector near the Ge detector and these objects were found to not have an effect on the total-to-peak ratios within the precision of the experiment.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>