<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T17:15:19Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/32870" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/32870</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Simona Socrate.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Charenkavanich, Panasaya</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-05-15T20:35:55Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-05-15T20:35:55Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/32870</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">62588032</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2005.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaf 29).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Cervical insufficiency is a condition in pregnancy in which the cervix asymptomatically dilates in the absence of uterine contractions, resulting in a spontaneous preterm delivery. The condition is often misdiagnosed and presents a significant challenge for the clinical community. In order to establish better diagnostic criteria for cervical insufficiency and to improve assessment of preterm delivery risk for the individual patient, a non-invasive medical imaging tool, which uses ultrasound elastography to test the mechanical properties of cervical tissue, has been developed. The hand-held ultrasound indentation system will enable in vivo collection of stress-strain data from patients that will provide researchers with the necessary information to be used in material modeling and improve diagnosis of cervical insufficiency. The device consists of an ultrasound probe, enclosed by a gel-filled cover. The mechanical properties of the covers vary with each cap as well as with time and temperature. Therefore, in order to ensure accurate measurement, the probe covers must be calibrated prior to use. An experimental study was carried out to examine the effects of various testing conditions on the mechanical behavior of the probe covers. Different freezing and thawing techniques were explored in order to determine favorable conditions in order to preserve the integrity of the probes between the time of manufacture and actual use. From the results of the research, the appropriate combination of testing conditions for probe calibration was determined, as well as freezing and thawing techniques for probe preservation.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Panasaya Charenkavanich.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">29 leaves</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">1438536 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">1437251 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Calibration of sonographic gel probe covers for in-vivo mechanical testing</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="e97a4852-eadc-4994-aa10-bef737759ed1">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Calibration of sonographic gel probe covers for in-vivo mechanical testing&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2005&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Charenkavanich, Panasaya&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Cervical insufficiency is a condition in pregnancy in which the cervix asymptomatically dilates in the absence of uterine contractions, resulting in a spontaneous preterm delivery. The condition is often misdiagnosed and presents a significant challenge for the clinical community. In order to establish better diagnostic criteria for cervical insufficiency and to improve assessment of preterm delivery risk for the individual patient, a non-invasive medical imaging tool, which uses ultrasound elastography to test the mechanical properties of cervical tissue, has been developed. The hand-held ultrasound indentation system will enable in vivo collection of stress-strain data from patients that will provide researchers with the necessary information to be used in material modeling and improve diagnosis of cervical insufficiency. The device consists of an ultrasound probe, enclosed by a gel-filled cover. The mechanical properties of the covers vary with each cap as well as with time and temperature. Therefore, in order to ensure accurate measurement, the probe covers must be calibrated prior to use. An experimental study was carried out to examine the effects of various testing conditions on the mechanical behavior of the probe covers. Different freezing and thawing techniques were explored in order to determine favorable conditions in order to preserve the integrity of the probes between the time of manufacture and actual use. From the results of the research, the appropriate combination of testing conditions for probe calibration was determined, as well as freezing and thawing techniques for probe preservation.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>