<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T10:57:35Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/32972" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/32972</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Ian W. Hunter.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Lin, Jiengju J. (Jiengju James)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-05-15T20:42:55Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-05-15T20:42:55Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/32972</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">62861901</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2005.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 47-48).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Constant denaturant capillary electrophoresis (CDCE) is a DNA separation technique that allows the detection of mutants at a fraction of 10Ì⁻⁶. CDCE uses a region of constant temperature and constant denaturant concentration to separate fragments with distinct melting points. The concept of the Ultra-high Throughput Mutational Spectrometer (UTMS) will perform massively parallel CDCE on a 100 by 100 capillary array. A modular aluminum structure was designed for the instrument to provide a chamber to house the array and modulate the flow of coolant, providing temperature control. The first iteration of the structure experienced leakage problems, which this project rectified. The structure was also modified to interface with a gel loading mechanism below, and the LED fluorescent excitation array above. The current subunit will enable the testing the complete UTMS system. In addition, an immersion heater was installed in the water-tight structure to simulate the 200 to 275 W heat dissipation within the chamber, caused by Joule heating in the capillary array. Correlation of a theoretical model to experimental data characterized and verified the transient thermal response of the system.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Jiengju J. Lin.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">51 p.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">2597107 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">2597858 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Manufacturing improvement and thermal property characterization of the frame structure of an Ultra-high Throughput Mutational Spectrometer</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="81ed1c5c-3ae2-41c4-91b6-906a2bf238f3">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Manufacturing improvement and thermal property characterization of the frame structure of an Ultra-high Throughput Mutational Spectrometer&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2005&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Lin, Jiengju J. (Jiengju James)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Constant denaturant capillary electrophoresis (CDCE) is a DNA separation technique that allows the detection of mutants at a fraction of 10Ì&amp;#132;⁻⁶. CDCE uses a region of constant temperature and constant denaturant concentration to separate fragments with distinct melting points. The concept of the Ultra-high Throughput Mutational Spectrometer (UTMS) will perform massively parallel CDCE on a 100 by 100 capillary array. A modular aluminum structure was designed for the instrument to provide a chamber to house the array and modulate the flow of coolant, providing temperature control. The first iteration of the structure experienced leakage problems, which this project rectified. The structure was also modified to interface with a gel loading mechanism below, and the LED fluorescent excitation array above. The current subunit will enable the testing the complete UTMS system. In addition, an immersion heater was installed in the water-tight structure to simulate the 200 to 275 W heat dissipation within the chamber, caused by Joule heating in the capillary array. Correlation of a theoretical model to experimental data characterized and verified the transient thermal response of the system.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>