<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T04:43:25Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/33121" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/33121</identifier><datestamp>2022-01-13T07:54:29Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Lynette A. Jones.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Deo, Nikhila</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-06-19T17:42:45Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-06-19T17:42:45Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/33121</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">62239232</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2005.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaves 68-71).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">This research focuses on the development of a wearable Physiological Sensor System (PSS) that can be used with a wireless tactile control unit to monitor the physiological status of a mobile user. Two physiological variables, heart rate and respiration rate, were selected for initial study, and technologies that could be used to measure these variables were evaluated. The PSS was required to be non-invasive, lightweight, and low-power. Initial studies indicated that heart rate could be most effectively measured using infrared light technology and so this was implemented in a wrist strap. It was determined that respiration rate could be recorded using a novel implementation of conducting polymer strain gages. For this purpose, polypyrrole-coated Lycra was fabricated and a chest strap was made that incorporated this sensor for recording respiration rate. Both sensors were connected to the PSS unit that was designed to provide the necessary signal processing, such as filtering and amplification, as well as produce the digital output signals that could be analyzed by the microcontroller in the tactile control unit. The complete circuit design process is described, from initial prototype development and testing to final layout and printed circuit board fabrication.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Nikhila Deo.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">M.Eng.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">92 leaves</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">4476526 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">4481181 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Physiological Sensor System for a wireless tactile display</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">PSS for a wireless tactile display</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="e317cc75-4a90-481c-bb61-83515eb3c5b8">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Physiological Sensor System for a wireless tactile display&lt;/Title>
   	&lt;Subtitle>PSS for a wireless tactile display&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2005&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Deo, Nikhila&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
   	&lt;Abstract>This research focuses on the development of a wearable Physiological Sensor System (PSS) that can be used with a wireless tactile control unit to monitor the physiological status of a mobile user. Two physiological variables, heart rate and respiration rate, were selected for initial study, and technologies that could be used to measure these variables were evaluated. The PSS was required to be non-invasive, lightweight, and low-power. Initial studies indicated that heart rate could be most effectively measured using infrared light technology and so this was implemented in a wrist strap. It was determined that respiration rate could be recorded using a novel implementation of conducting polymer strain gages. For this purpose, polypyrrole-coated Lycra was fabricated and a chest strap was made that incorporated this sensor for recording respiration rate. Both sensors were connected to the PSS unit that was designed to provide the necessary signal processing, such as filtering and amplification, as well as produce the digital output signals that could be analyzed by the microcontroller in the tactile control unit. The complete circuit design process is described, from initial prototype development and testing to final layout and printed circuit board fabrication.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>