<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T22:31:26Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/33629" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/33629</identifier><datestamp>2022-01-25T21:27:02Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Ian H. Hutchinson.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Youngblood, Brian Joaquin</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Nuclear Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Massachusetts Institute of Technology. Department of Nuclear Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Nuclear Science and Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-07-31T15:18:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-07-31T15:18:24Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2004</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/33629</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">64392602</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2004.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaves 75-76).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Bolometry is a diagnostic technique common to most tokamak fusion experiments. Bolometers are so widespread because they provide an important measure of the energy lost from confined plasmas as radiation, as well as being relatively simple and resilient in their construction. Here the bolometric diagnostics of the Alcator C-mod tokamak, their function, limitations, and the details of their calibration, operation, and maintenance are covered. In addition, the results of a variety of investigations into the behavior of C-mod plasmas as observed by bolometers are presented and discussed. The measurements dealt with are either measurements of total power radiated by the plasma or measurements of radial emissivity profiles. Measurements of the first kind are suitable for studying the effects of factors like net input power while measurements of the second kind are useful for studying the effects of factors like local temperature profiles and plasma composition.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Brian Joaquin Youngblood.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">76 leaves</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">3093476 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">3096585 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Nuclear Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Bolometer diagnostics on Alcator C-mod</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="d27f36c2-b6a2-47dd-ba12-2ef2f2727f47">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Bolometer diagnostics on Alcator C-mod&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2004&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Youngblood, Brian Joaquin&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Nuclear Engineering.&lt;/Keyword>
   	&lt;Abstract>Bolometry is a diagnostic technique common to most tokamak fusion experiments. Bolometers are so widespread because they provide an important measure of the energy lost from confined plasmas as radiation, as well as being relatively simple and resilient in their construction. Here the bolometric diagnostics of the Alcator C-mod tokamak, their function, limitations, and the details of their calibration, operation, and maintenance are covered. In addition, the results of a variety of investigations into the behavior of C-mod plasmas as observed by bolometers are presented and discussed. The measurements dealt with are either measurements of total power radiated by the plasma or measurements of radial emissivity profiles. Measurements of the first kind are suitable for studying the effects of factors like net input power while measurements of the second kind are useful for studying the effects of factors like local temperature profiles and plasma composition.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>