<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T05:49:48Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/34412" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/34412</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Hugh Herr and Ernesto Blanco.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Valiente, Andrew (Andrew J.)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-11-07T12:00:47Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-11-07T12:00:47Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/34412</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">70272243</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2005.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Page 114 blank.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 97-99).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Biomechanical experiments suggest that it may be possible to build a leg exoskeleton to reduce the metabolic cost of walking while carrying a load. A quasi-passive, leg exoskeleton is presented that is designed to assist the human in carrying a 75 lb payload. The exoskeleton structure runs parallel to the legs, transferring payload forces to the ground. In an attempt to make the exoskeleton more efficient, passive hip and ankle springs are employed to store and release energy throughout the gait cycle. To reduce knee muscular effort, a variable damper is implemented at the knee to support body weight throughout early stance. In this thesis, I hypothesize that a quasi-passive leg exoskeleton of this design will improve metabolic walking economy for carrying a 751b backpack compared with a leg exoskeleton without any elastic energy storage or variable-damping capability. I further anticipate that the quasi-passive leg exoskeleton will improve walking economy for carrying a 751b backpack compared with unassisted loaded walking. To test these hypotheses, the rate of oxygen consumption is measured on one human test participant walking on a level surface at a self-selected speed. Pilot experimental data show that the quasi-passive exoskeleton increases the metabolic cost of carrying a 751b backpack by 39% compared to carrying 75 lbs without an exoskeleton. When the variable-damper knees are replaced by simple pin joints, the metabolic cost relative to unassisted load carrying decreases to 34%, suggesting that the dampening advantages of the damper knees did not compensate for their added mass.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">(cont.) When the springs are removed from the aforementioned pin knee exoskeleton, the metabolic cost relative to unassisted load carrying increased to 83%. These results indicate that the implementation of springs is beneficial in exoskeleton design.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Andrew Valiente.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">114 p.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">5431927 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">5438675 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Design of a quasi-passive parallel leg exoskeleton to augment load carrying for walking</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="ad413b2a-9185-49ae-812d-7ff7e07e6c2f">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Design of a quasi-passive parallel leg exoskeleton to augment load carrying for walking&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2005&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Valiente, Andrew (Andrew J.)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Biomechanical experiments suggest that it may be possible to build a leg exoskeleton to reduce the metabolic cost of walking while carrying a load. A quasi-passive, leg exoskeleton is presented that is designed to assist the human in carrying a 75 lb payload. The exoskeleton structure runs parallel to the legs, transferring payload forces to the ground. In an attempt to make the exoskeleton more efficient, passive hip and ankle springs are employed to store and release energy throughout the gait cycle. To reduce knee muscular effort, a variable damper is implemented at the knee to support body weight throughout early stance. In this thesis, I hypothesize that a quasi-passive leg exoskeleton of this design will improve metabolic walking economy for carrying a 751b backpack compared with a leg exoskeleton without any elastic energy storage or variable-damping capability. I further anticipate that the quasi-passive leg exoskeleton will improve walking economy for carrying a 751b backpack compared with unassisted loaded walking. To test these hypotheses, the rate of oxygen consumption is measured on one human test participant walking on a level surface at a self-selected speed. Pilot experimental data show that the quasi-passive exoskeleton increases the metabolic cost of carrying a 751b backpack by 39% compared to carrying 75 lbs without an exoskeleton. When the variable-damper knees are replaced by simple pin joints, the metabolic cost relative to unassisted load carrying decreases to 34%, suggesting that the dampening advantages of the damper knees did not compensate for their added mass.&lt;/Abstract>
   	&lt;Abstract>(cont.) When the springs are removed from the aforementioned pin knee exoskeleton, the metabolic cost relative to unassisted load carrying increased to 83%. These results indicate that the implementation of springs is beneficial in exoskeleton design.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>