<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-20T17:50:09Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/34456" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/34456</identifier><datestamp>2022-01-25T21:40:25Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Pavel Hejzlar.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Cochran, Peter A. (Peter Andrew)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Nuclear Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department" lang="en_US">Massachusetts Institute of Technology. Department of Nuclear Engineering</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Nuclear Science and Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2006-11-07T12:21:30Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2006-11-07T12:21:30Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2005</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/34456</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">70715422</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 2005.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">The goal of this thesis is to design an experimental thermal-hydraulic loop capable of generating accurate, reliable data in various convection heat transfer regimes for use in the formulation of a comprehensive convection heat transfer correlation. The initial focus of the design is to ensure that the loop will be able to generate the convection flow regimes found in post Loss of Coolant Accident (LOCA) operation of a Gas-cooled Fast Reactor (GFR). As a result a scaling analysis of the proposed test facility was undertaken to demonstrate that the proposed loop would be able to operate in these aforementioned regimes. Having verified that the experimental loop could operate in the regimes of interest the next stage in the project was construction of the loop. Following construction of the loop and necessary instrumentation, an uncertainty analysis of the facility was conducted with the goal of determining the uncertainty associated with the calculation of heat transfer coefficients from the experimental data. The initial results were discouraging as the uncertainty calculated was large, ranging from -10-60%. After performing a heat transfer coefficient uncertainty analysis, we observed that the bulk of the uncertainty was clue to heat loss from the fluid to the environment.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">(cont.) Therefore, guard heaters were implemented into the loop design, to match the inner surface temperature of the insulation to the wall temperature of the test section, which allows minimization of heat loss to about zero. This resulted in the considerable reduction in heat transfer coefficient uncertainty to -8-15%.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Peter A. Cochran.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">85 leaves</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">3764234 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">3767725 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Nuclear Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Design of an experimental loop for post-LOCA heat transfer regimes in a Gas-cooled Fast Reactor</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Experimental loop for post-Loss of Coolant Accident heat transfer regimes in a GFR</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="83b68be6-7957-4546-8208-fc31a2333d1c">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Design of an experimental loop for post-LOCA heat transfer regimes in a Gas-cooled Fast Reactor&lt;/Title>
   	&lt;Subtitle>Experimental loop for post-Loss of Coolant Accident heat transfer regimes in a GFR&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2005&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Cochran, Peter A. (Peter Andrew)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Nuclear Engineering.&lt;/Keyword>
   	&lt;Abstract>The goal of this thesis is to design an experimental thermal-hydraulic loop capable of generating accurate, reliable data in various convection heat transfer regimes for use in the formulation of a comprehensive convection heat transfer correlation. The initial focus of the design is to ensure that the loop will be able to generate the convection flow regimes found in post Loss of Coolant Accident (LOCA) operation of a Gas-cooled Fast Reactor (GFR). As a result a scaling analysis of the proposed test facility was undertaken to demonstrate that the proposed loop would be able to operate in these aforementioned regimes. Having verified that the experimental loop could operate in the regimes of interest the next stage in the project was construction of the loop. Following construction of the loop and necessary instrumentation, an uncertainty analysis of the facility was conducted with the goal of determining the uncertainty associated with the calculation of heat transfer coefficients from the experimental data. The initial results were discouraging as the uncertainty calculated was large, ranging from -10-60%. After performing a heat transfer coefficient uncertainty analysis, we observed that the bulk of the uncertainty was clue to heat loss from the fluid to the environment.&lt;/Abstract>
   	&lt;Abstract>(cont.) Therefore, guard heaters were implemented into the loop design, to match the inner surface temperature of the insulation to the wall temperature of the test section, which allows minimization of heat loss to about zero. This resulted in the considerable reduction in heat transfer coefficient uncertainty to -8-15%.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>