<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-21T01:04:10Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/35309" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/35309</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Ian W. Hunter.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Wendell, Dawn M. (Dawn Marie), 1983-</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2007-01-10T15:38:28Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2007-01-10T15:38:28Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/35309</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">76759875</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, June 2006.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">This electronic version was submitted by the student author.  The certified thesis is available in the Institute Archives and Special Collections.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">"May 2006."</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaves 32-33).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Current needle-free injection technology is based on actuation via compressed springs or gas. These devices are not easy to modify for different depths of injections. This thesis describes the design and verification of a handheld needle-free device which is capable of various injection depths via electrical control of a Lorentz-force voice coil actuator. A benchtop proof-of-concept device was created to prove the concept of needle-free injection using a voice coil. After the successful testing of the proof-of-concept device, a handheld prototype was designed, manufactured, and tested. The controllability of injections was tested on excised sheep tissue in-vitro. The handheld device was also tested in-vivo on sheep midside and was shown to give comparable injections to a needle for delivery of the drug collagenase. The controllable needle-free injection principles described in this thesis could be used in human or veterinary applications.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Dawn M. Wendell.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">45 leaves</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">3202973 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent">3202557 bytes</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Controllable needle-free injection : development and verification of a novel device</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="29750e1d-e2ca-42b7-a79a-fe1a9a89234b">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Controllable needle-free injection : development and verification of a novel device&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2006&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Wendell, Dawn M. (Dawn Marie), 1983-&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Current needle-free injection technology is based on actuation via compressed springs or gas. These devices are not easy to modify for different depths of injections. This thesis describes the design and verification of a handheld needle-free device which is capable of various injection depths via electrical control of a Lorentz-force voice coil actuator. A benchtop proof-of-concept device was created to prove the concept of needle-free injection using a voice coil. After the successful testing of the proof-of-concept device, a handheld prototype was designed, manufactured, and tested. The controllability of injections was tested on excised sheep tissue in-vitro. The handheld device was also tested in-vivo on sheep midside and was shown to give comparable injections to a needle for delivery of the drug collagenase. The controllable needle-free injection principles described in this thesis could be used in human or veterinary applications.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>