<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T20:13:15Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/36187" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/36187</identifier><datestamp>2022-01-13T07:54:29Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Daniel K. Sodickson.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Lattanzi, Riccardo</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2007-02-21T11:59:45Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2007-02-21T11:59:45Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2006</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/36187</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">75206589</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2006.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 67-70).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Parallel MRI techniques allow acceleration of MR imaging beyond traditional speed limits. In parallel MRI, arrays of radiofrequency (RF) detector coil arrays are used to perform some degree of spatial encoding which complements traditional encoding using magnetic field gradients. As the acceleration factor increases, coil design becomes critical to the overall image quality. The quality of a design is commonly judged on how it compares with other coil configurations. A procedure to evaluate the absolute performance of RF coil arrays is proposed. Electromagnetic calculations to compute the ultimate intrinsic signal-to-noise ratio (SNR) available for any physically realizable coil array are shown, and coil performance maps are generated based on the ratio of experimentally measured SNR to this ultimate intrinsic SNR.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Riccardo Lattanzi.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">70 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Electrical Engineering and Computer Science.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Radiofrequency detector coil performance maps for parallel MRI applications</dim:field>
   <dim:field mdschema="dc" element="title" qualifier="alternative" lang="en_US">Radio frequency detector coil performance maps for parallel magnetic resonance imaging applications</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="18393be5-51ea-44a5-93e5-a4fab61096f4">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Radiofrequency detector coil performance maps for parallel MRI applications&lt;/Title>
   	&lt;Subtitle>Radio frequency detector coil performance maps for parallel magnetic resonance imaging applications&lt;/Subtitle>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2006&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Lattanzi, Riccardo&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Electrical Engineering and Computer Science.&lt;/Keyword>
   	&lt;Abstract>Parallel MRI techniques allow acceleration of MR imaging beyond traditional speed limits. In parallel MRI, arrays of radiofrequency (RF) detector coil arrays are used to perform some degree of spatial encoding which complements traditional encoding using magnetic field gradients. As the acceleration factor increases, coil design becomes critical to the overall image quality. The quality of a design is commonly judged on how it compares with other coil configurations. A procedure to evaluate the absolute performance of RF coil arrays is proposed. Electromagnetic calculations to compute the ultimate intrinsic signal-to-noise ratio (SNR) available for any physically realizable coil array are shown, and coil performance maps are generated based on the ratio of experimentally measured SNR to this ultimate intrinsic SNR.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>