<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-18T21:13:46Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/36245" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/36245</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Ian W. Hunter.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Pavlov, Atanas (Atanas Ivanov)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2007-02-21T13:14:00Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2007-02-21T13:14:00Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/36245</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">77274870</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">"June 2006."</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaves 93-94).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">A recent advancement in the area of needle-free injection systems has been the development of devices capable of epidermal delivery of powder medications. These devices use high-pressure compressed gas to accelerate drug particles 2 to 50 gpm in size to velocities of 200 to 1000 m/s. At these speeds the particles have sufficient momentum to penetrate the skin barrier and reach the viable epidermal layers. The devices offer much better control over the depth of penetration than traditional hypodermic needles, a factor particularly important in vaccine delivery. However they still have not found wide spread use, because of their cost. We studied the parameters determining the performance of these devices and used that knowledge to create a simple and reusable device capable of delivering 3 to 10 mg of powder formulation to the viable epidermis. Furthermore we showed that hydrogen-oxygen combustion could be used to create the shock wave required to accelerate the drug particles. This proves that portable reusable devices powered by hydrogen can be constructed and used for vaccine and medication delivery.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Atanas Pavlov.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">94 leaves</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Needle-free drug delivery using shock wave techniques</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="2a5c630a-3bf8-4b4a-8743-278662a9229d">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Needle-free drug delivery using shock wave techniques&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2006&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Pavlov, Atanas (Atanas Ivanov)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>A recent advancement in the area of needle-free injection systems has been the development of devices capable of epidermal delivery of powder medications. These devices use high-pressure compressed gas to accelerate drug particles 2 to 50 gpm in size to velocities of 200 to 1000 m/s. At these speeds the particles have sufficient momentum to penetrate the skin barrier and reach the viable epidermal layers. The devices offer much better control over the depth of penetration than traditional hypodermic needles, a factor particularly important in vaccine delivery. However they still have not found wide spread use, because of their cost. We studied the parameters determining the performance of these devices and used that knowledge to create a simple and reusable device capable of delivering 3 to 10 mg of powder formulation to the viable epidermis. Furthermore we showed that hydrogen-oxygen combustion could be used to create the shock wave required to accelerate the drug particles. This proves that portable reusable devices powered by hydrogen can be constructed and used for vaccine and medication delivery.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>