<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T09:47:09Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/36738" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/36738</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Lynette A. Jones.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Lam, Amy R. (Amy Rebecca)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2007-03-12T17:49:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2007-03-12T17:49:11Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2006</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2006</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/36738</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">77564719</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaves 27-28).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">This research focused on the evaluation of a tactile display that is used for navigation and communication. In the first experiment, a four by four array of vibrating motors (tactors) was mounted on the torso while the subject wore an Interceptor Body Armor (IBA) vest. Subjects were required to identify which of eight patterns was presented. The results indicated that subjects could recognize the patterns presented with perfect accuracy, which indicates that wearing heavy body armor over the display does not affect the ability to perceive tactile inputs. A second set of experiments involved a one-dimension tactile array of eight tactors worn around the waist. The results indicated that the subjects could recognize the six circumferential patterns presented with an accuracy of 98-100% correct. A further experiment confirmed that the linear tactile display could be used to provide cues about the location of an event in the environment. These experiments showed that identification of the vibrotactile patterns was slightly superior on the two-dimension tactile array on the torso as compared to the one-dimension tactile array around the waist.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">(cont.) When subjects were required to identify the location of an individual vibrating motor using the one-dimensional array they achieved an accuracy of 94-100% correct. This suggests that a linear tactile array can be used to present navigational cues.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Amy R. Lam.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">28 leaves</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Vibrotactile pattern recognition on the torso with one and two dimensional displays</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="f9127bbb-e619-4d7b-8668-8c3eaa8f146f">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Vibrotactile pattern recognition on the torso with one and two dimensional displays&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2006&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Lam, Amy R. (Amy Rebecca)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>This research focused on the evaluation of a tactile display that is used for navigation and communication. In the first experiment, a four by four array of vibrating motors (tactors) was mounted on the torso while the subject wore an Interceptor Body Armor (IBA) vest. Subjects were required to identify which of eight patterns was presented. The results indicated that subjects could recognize the patterns presented with perfect accuracy, which indicates that wearing heavy body armor over the display does not affect the ability to perceive tactile inputs. A second set of experiments involved a one-dimension tactile array of eight tactors worn around the waist. The results indicated that the subjects could recognize the six circumferential patterns presented with an accuracy of 98-100% correct. A further experiment confirmed that the linear tactile display could be used to provide cues about the location of an event in the environment. These experiments showed that identification of the vibrotactile patterns was slightly superior on the two-dimension tactile array on the torso as compared to the one-dimension tactile array around the waist.&lt;/Abstract>
   	&lt;Abstract>(cont.) When subjects were required to identify the location of an individual vibrating motor using the one-dimensional array they achieved an accuracy of 94-100% correct. This suggests that a linear tactile array can be used to present navigational cues.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>