<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T06:26:30Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/38705" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/38705</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131023</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Haruhiko H. Asada.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Marinković, Aleksandar, S.M. Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2007-08-29T20:47:12Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2007-08-29T20:47:12Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2007</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2007</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/38705</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">166143503</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2007.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaves 51-54).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">An important part of a routine clinical examination is the assessment of the arterial blood pressure waveform. The variations in shape of the waveform indicate the presence of disease. In this work, a method is developed for the reconstruction of arterial blood pressure waveform using the signals obtained from a noninvasive wearable photoplethysmographic Ring Sensor and hydrostatic pressure variations measured by an Arm Accelerometer Sensor. A dynamic model with the Wiener model structure is used to establish the relationship between transmural pressure and photoplethysmographic signal. Tuned nonlinear dynamic model has been shown to be capable of estimating the arterial blood pressure waveform. The algorithm has been applied to experimental blood pressure measurements in a healthy subject and shown to provide accurate waveform reconstruction. As a result, the use of a wearable photoplethysmographic Ring Sensor can be extended to provide a finger arterial blood pressure waveform.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Aleksandar Marinković.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.M.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">54 leaves</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Reconstructing the blood pressure waveform using a wearable photoplethysmograph sensor and hydrostatic pressure variations measured by accelerometers</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="ecc4076f-1895-4c70-832c-07f713ed2388">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Reconstructing the blood pressure waveform using a wearable photoplethysmograph sensor and hydrostatic pressure variations measured by accelerometers&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2007&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Marinković, Aleksandar, S.M. Massachusetts Institute of Technology&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License&gt;http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>An important part of a routine clinical examination is the assessment of the arterial blood pressure waveform. The variations in shape of the waveform indicate the presence of disease. In this work, a method is developed for the reconstruction of arterial blood pressure waveform using the signals obtained from a noninvasive wearable photoplethysmographic Ring Sensor and hydrostatic pressure variations measured by an Arm Accelerometer Sensor. A dynamic model with the Wiener model structure is used to establish the relationship between transmural pressure and photoplethysmographic signal. Tuned nonlinear dynamic model has been shown to be capable of estimating the arterial blood pressure waveform. The algorithm has been applied to experimental blood pressure measurements in a healthy subject and shown to provide accurate waveform reconstruction. As a result, the use of a wearable photoplethysmographic Ring Sensor can be extended to provide a finger arterial blood pressure waveform.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>