<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T17:13:36Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/39899" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/39899</identifier><datestamp>2022-01-13T07:54:36Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131022</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">Ian W. Hunter.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Forest, Craig Richard, 1978-</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Mechanical Engineering</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2008-01-10T15:54:06Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2008-01-10T15:54:06Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2007</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2007</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/39899</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">182546139</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2007.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (p. 221-243).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">Discovering the genetic causes of common diseases may require scanning for mutations in all of the genes in a million people, a significant undertaking. Such discoveries would revolutionize biotechnology, potentially enabling simple genetic tests for risk and targeted preventative or therapeutic strategies. An increase in throughput of genetic analysis instrumentation by several orders of magnitude is essential to undertake such an ambitious task. In this thesis, progress will be presented towards the creation of such a "mutational spectrometer" instrument containing up to 10,000 capillary channels and enabled with subsystems for loading, separating, and detecting fluorescently-labeled DNA. Challenges include DNA manipulation, optical signal detection, macro/micro design integration, precision alignment and assembly, and thermal control. To manipulate DNA, we have utilized a bioMEMS design platform for interfacing to an array of separation channels that enables electrokinetic biomolecule loading, detection, and fraction collection in independent wells.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">(cont.) Signal detection is accomplished by a sensitive (107 molecule limit-of-detection), scalable (to 10,000 independent channels), end-of-column fluorescence detection technology that accommodates tightly packed capillary arrays as required for ultra-high throughput electrophoretic separation. Capillary array assembly and constraint technologies have been developed for 2-D arrays containing as many as 10,000 replaceable capillaries. Thermal control requirements of 0.3 °C over the entire 10,000 channel array are met with a cross-flow water heat exchanger. Additional subsystems for forcing a viscous polymer matrix into the capillaries, and interfacing the capillary array to a fluid reservoir for electrophoresis have also been developed, as required. This work lays the foundation for the realization of a mutational spectrometer instrument that will enable population-wide pangenomic analyses to uncover the genetic causes of common diseases.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Craig Richard Forest.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">Ph.D.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">243 p.</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Mechanical Engineering.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">An ultra-high throughput mutational spectrometer for human genetic diagnostics</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="07c7aa5f-0dc3-434e-95a1-ad5e3c5344ff">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>An ultra-high throughput mutational spectrometer for human genetic diagnostics&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2007&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author&gt;
        	&lt;DisplayName>Forest, Craig Richard, 1978-&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Mechanical Engineering.&lt;/Keyword>
   	&lt;Abstract>Discovering the genetic causes of common diseases may require scanning for mutations in all of the genes in a million people, a significant undertaking. Such discoveries would revolutionize biotechnology, potentially enabling simple genetic tests for risk and targeted preventative or therapeutic strategies. An increase in throughput of genetic analysis instrumentation by several orders of magnitude is essential to undertake such an ambitious task. In this thesis, progress will be presented towards the creation of such a &amp;quot;mutational spectrometer&amp;quot; instrument containing up to 10,000 capillary channels and enabled with subsystems for loading, separating, and detecting fluorescently-labeled DNA. Challenges include DNA manipulation, optical signal detection, macro/micro design integration, precision alignment and assembly, and thermal control. To manipulate DNA, we have utilized a bioMEMS design platform for interfacing to an array of separation channels that enables electrokinetic biomolecule loading, detection, and fraction collection in independent wells.&lt;/Abstract>
   	&lt;Abstract>(cont.) Signal detection is accomplished by a sensitive (107 molecule limit-of-detection), scalable (to 10,000 independent channels), end-of-column fluorescence detection technology that accommodates tightly packed capillary arrays as required for ultra-high throughput electrophoretic separation. Capillary array assembly and constraint technologies have been developed for 2-D arrays containing as many as 10,000 replaceable capillaries. Thermal control requirements of 0.3 °C over the entire 10,000 channel array are met with a cross-flow water heat exchanger. Additional subsystems for forcing a viscous polymer matrix into the capillaries, and interfacing the capillary array to a fluid reservoir for electrophoresis have also been developed, as required. This work lays the foundation for the realization of a mutational spectrometer instrument that will enable population-wide pangenomic analyses to uncover the genetic causes of common diseases.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>