<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-09-19T15:36:31Z</responseDate><request verb="GetRecord" identifier="oai:dspace.mit.edu:1721.1/40899" metadataPrefix="dim">https://dspace.mit.edu/server/oai/request</request><GetRecord><record><header><identifier>oai:dspace.mit.edu:1721.1/40899</identifier><datestamp>2022-01-13T07:54:41Z</datestamp><setSpec>com_1721.1_7582</setSpec><setSpec>com_1721.1_7581</setSpec><setSpec>col_1721.1_131024</setSpec></header><metadata><dim:dim xmlns:dim="http://www.dspace.org/xmlns/dspace/dim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:doc="http://www.lyncode.com/xoai" xsi:schemaLocation="http://www.dspace.org/xmlns/dspace/dim http://www.dspace.org/schema/dim.xsd">
   <dim:field mdschema="dc" element="contributor" qualifier="advisor" lang="en_US">John E. Rice.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="author" lang="en_US">Gamboa, Eliseo (Eliseo J.)</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="other" lang="en_US">Massachusetts Institute of Technology. Dept. of Physics.</dim:field>
   <dim:field mdschema="dc" element="contributor" qualifier="department">Massachusetts Institute of Technology. Department of Physics</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="accessioned">2008-03-27T18:21:07Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="available">2008-03-27T18:21:07Z</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="copyright" lang="en_US">2007</dim:field>
   <dim:field mdschema="dc" element="date" qualifier="issued" lang="en_US">2007</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="uri">http://hdl.handle.net/1721.1/40899</dim:field>
   <dim:field mdschema="dc" element="identifier" qualifier="oclc" lang="en_US">197105970</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2007.</dim:field>
   <dim:field mdschema="dc" element="description" lang="en_US">Includes bibliographical references (leaves 59-60).</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="abstract" lang="en_US">A pulse height analysis (PHA) system has been installed on the Alcator C-Mod magnetic confinement fusion experiment. The PHA utilizes a Si(Li) detector to measure soft X-rays in the 1-30 keV range with an energy resolution on the order of 100eV. A FASTComtec MCA-3 multichannel analyzer allows integration times of ims while the PHA supports counting rates of up to 80kHz. The thermal electron temperature is measured from the energy dependence of the intensity of the electron bremsstrahlung spectrum. Measurements of line radiation allows the PHA to identify impurity ions within each plasma shot. The result is a diagnostic that measures thermal electron temperatures while aiding in the indentification of heavy (Z 12) impurities.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="statementofresponsibility" lang="en_US">by Eliseo Gamboa.</dim:field>
   <dim:field mdschema="dc" element="description" qualifier="degree" lang="en_US">S.B.</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="extent" lang="en_US">60 leaves</dim:field>
   <dim:field mdschema="dc" element="language" qualifier="iso" lang="en_US">eng</dim:field>
   <dim:field mdschema="dc" element="publisher" lang="en_US">Massachusetts Institute of Technology</dim:field>
   <dim:field mdschema="dc" element="rights" lang="en_US">M.I.T. theses are protected by 
copyright. They may be viewed from this source for any purpose, but 
reproduction or distribution in any format is prohibited without written 
permission. See provided URL for inquiries about permission.</dim:field>
   <dim:field mdschema="dc" element="rights" qualifier="uri" lang="en_US">http://dspace.mit.edu/handle/1721.1/7582</dim:field>
   <dim:field mdschema="dc" element="subject" lang="en_US">Physics.</dim:field>
   <dim:field mdschema="dc" element="title" lang="en_US">Alcator C-Mod soft X-ray pulse height analysis system</dim:field>
   <dim:field mdschema="dc" element="type" lang="en_US">Thesis</dim:field>
   <dim:field mdschema="dc" element="format" qualifier="mimetype">application/pdf</dim:field>
   <dim:field mdschema="dspace" element="authorsordered">false</dim:field>
   <dim:field mdschema="dspace" element="entity" qualifier="type">Publication</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="others" element="access-status">unknown</dim:field>
   <dim:field mdschema="cerif" element="openaire" authority="" confidence="-1">&lt;Publication xmlns="https://www.openaire.eu/cerif-profile/1.1/" id="fde442e5-cdae-4d4c-9025-e49f9bd7b86e">
	&lt;Type xmlns="https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types">http://purl.org/coar/resource_type/c_1843&lt;/Type>
	&lt;Language>eng&lt;/Language>
   	&lt;Title>Alcator C-Mod soft X-ray pulse height analysis system&lt;/Title>
   	&lt;PublishedIn>
    	&lt;Publication>
      	&lt;/Publication>
   	&lt;/PublishedIn>
   	&lt;PublicationDate>2007&lt;/PublicationDate>
   	&lt;Authors>
      	&lt;Author>
        	&lt;DisplayName>Gamboa, Eliseo (Eliseo J.)&lt;/DisplayName>
         	&lt;Affiliation>
         		&lt;OrgUnit>
         		&lt;/OrgUnit>
         	&lt;/Affiliation>
      	&lt;/Author>
	&lt;/Authors>
   	&lt;Editors>
	&lt;/Editors>
    &lt;Publishers>
        &lt;Publisher>
            &lt;DisplayName>Massachusetts Institute of Technology&lt;/DisplayName>
            &lt;OrgUnit />
        &lt;/Publisher>
    &lt;/Publishers>
    &lt;License>http://dspace.mit.edu/handle/1721.1/7582&lt;/License>
    &lt;Keyword>Physics.&lt;/Keyword>
   	&lt;Abstract>A pulse height analysis (PHA) system has been installed on the Alcator C-Mod magnetic confinement fusion experiment. The PHA utilizes a Si(Li) detector to measure soft X-rays in the 1-30 keV range with an energy resolution on the order of 100eV. A FASTComtec MCA-3 multichannel analyzer allows integration times of ims while the PHA supports counting rates of up to 80kHz. The thermal electron temperature is measured from the energy dependence of the intensity of the electron bremsstrahlung spectrum. Measurements of line radiation allows the PHA to identify impurity ions within each plasma shot. The result is a diagnostic that measures thermal electron temperatures while aiding in the indentification of heavy (Z 12) impurities.&lt;/Abstract>
	&lt;Access xmlns="http://purl.org/coar/access_right" 
    >
    &lt;/Access>
&lt;/Publication>
</dim:field>
</dim:dim>
</metadata></record></GetRecord></OAI-PMH>